IG0005_EN_ZERO V1.1

Not make holes in any part of the tank.

ACTIVATION PROCEDURE

The  activation  procedure  must  be  performed  to  the  first 

installation of the device, or whenever it is reset to factory 

defaults.

1.

 Move the magnet to the symbol ON (bottom left) and hold 

the position for about 15 seconds, and in any case until you 

hear a long tone.

4.

 Wait for the completion of the activation procedure 

indicated by 2 beeps in succession of 1 second (repeated 

every 2 seconds).

5.

 The operator will receive a SMS message from the web 

portal containing the installation data: 

terminal 000000015852 - ZERO is installed: Batt:3.708 GSM:17 

Level:56.7% Synchronization:T Working status:1

Check and verify the data as in table:

2. 

Wait an acoustic signal consisting of tones repeated. There 

are 3 possibilities:

a) 3 tones repeted every 5 seconds:

The GSM is registered and the quality of the signal is good.

b) 2 tones repeted every 5 seconds:

The GSM is registered but the quality of the signal is not good.

In this case the installation could to be not completed successfully

c) 1 tone repeated every 5 seconds:

The GSM is not registered or there are some troubles in the 

SIM card. In this case the installation will fail. 

3. 

Make the recording sequence in an appropriate manner by 

performing the procedure quickly:

- bring the magnet to the WK symbol (top left) and hold the 

position for about 5 seconds until you hear a long sound of 1 

beeps; remove the magnet.

-  bring back the magnet to the WK symbol within 3 seconds and  

hold the position for about 5 seconds until you hear a long 

sound of 2 beeps; remove the magnet.

3. 

Permanently attach the device, repositioning the front 

screw until it snaps.

Shitek Technology Srl

via Malerbe, 3 - 36040 Grumolo delle Abbadesse (VI) - Italia

Sede legale: Via San’Antonio, 45 - 35030 Veggiano (PD) - Italia

www.shitektechnology.com - [email protected]

-  bring back the magnet to the WK symbol within 3 seconds 

and hold the position for about 5 seconds until you hear a long 

sound of 3 beeps; remove the magnet.

NOTE: if the maintainer does not receive the SMS or e-mail 

with the report of the installation you need to contact the 

Shitek assistance service.

NOTE: to calculate the level, ZERO reads the angle of the 

magnetic field provided by the level indicator. 

It is advisable to replace the level indicator with a new one, 

since there is the certainty of the quality of the magnet of a old 

level indicator.

Shitek Technology Srl is not responsible for the quality and/or 

of the measure's error if the technical conditions do not comply 

with the requirements.

SERIAL NUMBER

LEVEL

BATTERY

GSM SIGNAL

00000000019573

57.3%

>3.5V

>7

INSTALLATION DATA

It is advisable to write in the table below the data of the installed 

device to align the setup information at the venue

SERIAL NUMBER
INSTALLATION CODE
ADDRESS

DESCRIPTION

TANK TYPE

HORIZZONTAL

VERTICAL

Reviews: