![Shinybow USA SB-5544BNC Instruction Manual Download Page 10](http://html1.mh-extra.com/html/shinybow-usa/sb-5544bnc/sb-5544bnc_instruction-manual_1258460010.webp)
8
REMOTE PROTOCOL COMMANDS
IR REMOTE CUSTOM AND DATA CODES (NEC Standard)
HOW TO SETUP IR CODES:
CUSTOM CODE: 20DF
POWER ON:
20DF A15E
LOCK:
20DF B54A
:
20DF
C33C
POWER OFF:
20DF A25D
RECALL:
20DF
B24D
VOLUME -:
20DF
C43B
ALL:
20DF B04F
MEMORY:
20DF
B44B
B:
20DF
EE11
OFF:
20DF B14E
ENTER:
20DF
B34C
BALANCE -:
20DF
ED12
PRESS TV DESTINATION - # then PRESS SOURCE - #
DESTINATION #1 : 20DF 01EF
SOURCE #1 : 20DF 01FE
DESTINATION #2 : 20DF 02DF
SOURCE #2 : 20DF 02FD
DESTINATION #3 : 20DF 03CF
SOURCE #3 : 20DF 03FC
DESTINATION #4 : 20DF 04BF
SOURCE #4 : 20DF 04FB
For Example:
Select Destination # 1 to show Source #1~4,
The IR Data Code list when press Destination # then press Source #
Press Destination # 1 & Source #1 20DF 01EF
20DF 01FE
Press Destination # 1 & Source #2 20DF 01EF
20DF 02FD
Press Destination # 1 & Source #3 20DF 01EF
20DF 03FC
Press Destination # 1 & Source #4 20DF 01EF
20DF 04FB