21
Temp range
16
℃
31
℃
(St+3)
℃
(St+2)
℃
Setting temp
St
Compressor ON
Compressor OFF
When Rt
≤
St+2
℃,
compressor
ON
.
When Rt
≥
St+3
℃,
compressor
OFF
When St+2
℃
<Rt<St+3
℃,
and the compressor
OFF
≥
6min
,
the compressor
ON
.
Auto operation
Timer
You can set timer to on/off in 24 hours
Timer on
Mode
Cooling(including auto)
Heating(including auto)
Dry(including auto)
Condition
Start time
Rt-St
≥
2
℃
St-Rt
≥
3
℃
45min before setting time
60min before setting time
On setting time
~
Setting temp range
19
℃
29
℃
~
Room temp before operation
Auto operation mode
Auto temp
21
℃
<tr<27
℃
tr
≥
27
℃
tr
≤
21
℃
cooling
dry
heating
27
℃
Room temp
tr
21
℃
After operation for 15 minutes,if you press "too warm"or"too cool"button,you can adjust the setting temp
±
2
℃.
Once start a mode,it will cost 2 hours,then you can choose another one.
≥
6min
Heating operation
System control