19(29)
F.04
Mixing mode
The number of layers of mixing action when it starts mixing.
For example: the suction time is 20sec, the mixing proportion
is 10%, the number of layers is 2, and then the mixing action
is 9s
—
1s ----9s---1s
Set single layer
’
s working, and the suction time range is 5-99
secs.
Set double layers
’
working, and the suction time range is
17-99 secs.
Set three layers
’
working, and the suction time range is 32-99
secs.
Set four layers
’
working, and the suction time range is 46-99
secs.
If the suction time changes, the min. action time is less than
1 sec. after calculation, and the program will force to change
the action time to 1 sec.
1
1-4times
F.05
Mixing action count cycle start setting
Count from the first start-up, and start once mixing action
after several times of repeated suction startings.
Set 1 as mixing materials every time.
Set [F.03] to 0 without mixing.
once
1-9 times
F.06
Setting time of cleaning before suction
Set 0 as the no screen cleaning before suction.
Corresponding action: R01
0 secs.
0-99
secs.
F.07
Setting time of screen cleaning after suction
Set 0 as no screen cleaning after suction.
Corresponding action: R11
5 secs.
0-99
secs.
F.08
Screen cleaning cycle
It starts once [F.06] or [F.07] cleaning action only after
several times of repeated suction actions.
Set 1 as cleaning the screen cleaning at every suction.
10 times
1-99
times
F.09
Circulating suction waiting time
Waiting time before a new suction action starts after each
suction action.
Set 0 as not waiting.
Waiting time before a new suction action starts
Corresponding action: N03
0
(Unit
10
secs.)
0-9990
F.10
Shortage metering alarm
Set the number of times that the material doesn
’
t fall into the
hopper, and it should alarm after several times of this error
occurs.
Alarm cleaning mode:
1.The alarm will dismiss when it feeds the materials again.
2. Ent key on the panel can be cancelled.
3.Turn on the power again.
Set 9 as cancelling this function.
Corresponding action: A.01
3
1-9 times