- 9 - 

 

negative(

) dial side and Strong (Crisp) welding arc can be obtained with Arc 

Control Dial positive(

) dial side. 

 

(4) ROD SELECTOR (for CC mode) 

The equipment incorporates Rod Selector feature. 

When the CV/CC Selector Switch is positioned at [CC-STICK, GOUGING], the 
welding characteristics can be switched by changing Rod Selector Switch. 
[CELLULOSE] mode is suitable for the Cellulose Rods and [OTHERS] mode is 
suitable for the Gouging Rods and ordinal rods except cellulose. 

 

5-3. Voltage Reduction Device 

The equipment incorporates VRD (Voltage Reduction Device) feature, for the 
purpose of protecting an operator from electric shock with welding output. 
When the VRD Selector Switch is turned to [ON], the voltage changes to 35V or less 
during no welding period. 
The equipment is incorporated with 
monitoring function of VRD. 
When the VRD Selector Switch is turned to 
[ON], Green VRD Lamp will be automatically 
turned on at [BELOW 35V] side. 
When the Red VRD lamp will be turned on at [AT OR ABOVE 35V] side, the welding 
voltage is exceeded more than 35V or while the VRD Selector switch is at [TEST] 
mode. 

 
5-4. Output Remote Control 

The equipment incorporates Optional Output Remote Control feature. 

 
(1) 14-Pin Connector (Wire Feeder Control) 

Wire Feeder Control operation is available by connecting the Optional Wire Feeder 

to the 14-Pin Connector 

 
 
 
 
 
 
 
 
 

(2) Welding Terminals Switch 

Wire Feeder Control operation is available by turning the Weld Terminals Switch to

 

[REMOTE CONTROL] position. 
When the Weld Terminals Switch to [WELD TERMINALS ON] position, the welding 
voltage is always supplied from machine’s welding terminal. 
When the Weld Terminals Switch to [REMOTE CONTROL] position, the welding 
voltage will be supplied from machine’s welding terminal by pressing the wire feeder 
torch trigger. 

(3) Wire Feeder Voltmeter Selector

 

The Wire Feeder Voltmeter Switch can change the voltmeter indication polarity

 

which is equipped on the optional wire feeder. 

(4) 42V / 115V Selector 

The 42V / 115V Selector Switch can change the supply voltage for the required 
output voltage based on the optional wire feeder specification. 
 

VRD 
LAMP 

WIRE FEEDER 

14-PIN   
CONECTOR 

Summary of Contents for DGW300MS

Page 1: ...Vertical Water Cooled 4 Cycle Diesel Engine CAUTION Do not operate the Generator Welder or any other appliance before you have read and understood the instructions for use and keep near for readily u...

Page 2: ......

Page 3: ...ease attach this manual and explain how to operate and have them read this manual if the equipment will be sub leased Please store this manual near the equipment for easy reference Replace damaged or...

Page 4: ...6 2 Checking Coolant Water 15 6 3 Checking Fuel 15 6 4 Checking Fuel Engine Oil and Water Leakage 16 6 5 Checking Battery 16 7 Operation the Engine 17 7 1 Starting 17 7 2 Stopping 18 7 3 Emergency Sto...

Page 5: ...ing the maintenance should always keep the key Danger Electromagnetic Interference Person with a pacemaker of the heart do not approach the equipment and welding around the work site during work May a...

Page 6: ...the engine and muffler during operation and immediately after stopping the equipment for the temperature could reach extremely high When checking engine oil or changing oil always stop the engine and...

Page 7: ...he following figure When ordering the new label use the following part numbers Suffocation from exhaust fume No X505 004900 Suffocation from welding fume No X505 004910 Electric shock No X505 004930 F...

Page 8: ...CD or Higher Lubrication Oil Volume L 3 8 Effective 1 4 Cooling Water Volume L 3 0 Sub Tank Capacity 0 6 L included Engine Starting Method Starter Motor Battery 46B24L Japan Industrial Standard Fuel...

Page 9: ...WITCH WELD TERMINAL SWITCH WIRE FEEDER VOLT METER SWITCH 42V 115V SELECTOR SWITCH CIRCUIT PROTECTOR FOR WIRE FEEDER FUEL METER STARTER SWITCH AC METER DC METER OPERATION MODE SELECTOR SWITCH EMERGENCY...

Page 10: ...PLUG WATER DRAIN PLUG RIGHT DOOR AIR CLEANER BATTERY FUSE 60A 10A FUEL LEVER FUEL STRAINER SUB TANK OIL GAUGE 1 P RECEPTACLE EARTH LEAKAGE CIRCUIT BREAKER ELCB 1 P BREAKER BONNET GROUNDING TERMINAL FO...

Page 11: ...racteristic feature Connecting a wire feeder and then turning the CC CV Selector Switch to CV WIRE semi automatic welding such as MIG MAG SS etc is available to perform Connecting the welding cables a...

Page 12: ...on at AT OR ABOVE 35V side the welding voltage is exceeded more than 35V or while the VRD Selector switch is at TEST mode 5 4 Output Remote Control The equipment incorporates Optional Output Remote Co...

Page 13: ...ELDER Both Welder and Generator mode WELDER ONLY Only welding function mode GEN ONLY Only generating function mode 5 6 Meter The equipment incorporates digital meters voltage amperage of welding outpu...

Page 14: ...erature rises abnormally the coolant water temperature monitor lamp will flash and the automatic shutoff will be engaged When this occurs check the coolant water reservoir tank and replenish if needed...

Page 15: ...Leakage Circuit Breaker and Grounding Danger Electric Shock Ground every grounding terminal to the earth as set out in the manual If even one of all is unconnected by mistake or accident it will be m...

Page 16: ...ition in between ON and OFF In the case stop the engine promptly and find the leakage point to repair After repairing leakage point s reset the ELCB by following procedure Push the ELCB lever down to...

Page 17: ...unintentional touching cooling fan and fan belt Caution Fire Burns Injuries When checking engine always stop the engine and keep away from fire Wait until the engine cools down before performing any i...

Page 18: ...prevent freeze and rust 30 mixture LLC is filled when shipped from factory Mixture ratio of the coolant should be 30 45 depending on the ambient temperature Replace LLC at every year or 2000 hours Mi...

Page 19: ...ur physician immediately Caution Explosion Do not use the equipment or charge the battery in the case the battery fluid level is lower than the LOWER level Battery may emit some combustible gas so kee...

Page 20: ...on Check to see if it is safe around the equipment before starting When operating the equipment by two or more persons ensure all work condition are safe Do not use the equipment on dusty hot and humi...

Page 21: ...t 5 minutes Turn the Starter Switch to STOP After the engine has stopped turn the every Fuel Lever to CLOSE Turn the Battery Isolator Switch to OFF position Caution When the engine does not stop in sp...

Page 22: ...38 8 2 Polarity There are two welding output terminals and Select the polarity according to the operation referring to the table below Caution Follow the instruction of the welding rods the polarity o...

Page 23: ...uty cycle represents 6 minutes of load and 4 minutes of no load in a 10 minutes period Caution The equipment may be damaged due to overheat if welding more than duty cycle 8 5 Welding Danger Electroma...

Page 24: ...sing 14 Pin Connector Turn the Weld Terminals Switch to WELD TERMINALS ON Turn the CV CC Selector Switch to CV WIRE Set the voltage by the Output Control Dial While using 14 Pin Connector Turn the 42V...

Page 25: ...ng the maintenance should always keep the key Ground the every grounding terminal to the earth as set out in the manual If even one of all is unconnected by mistake or accident it will be much more da...

Page 26: ...h Leakage Relay When any breaker has tripped restore the circuit breaker as per the following procedure Turn OFF all the power switches in the loads Turn push up the breaker to ON Caution Take care fo...

Page 27: ...in the case the battery fluid level is lower than the LOWER level Battery may emit some combustible gas so keep it away from fire and sparks To optimize the use of this generator welder we recommend t...

Page 28: ...16 Adjust Tension V Belt 1st 2 nd or after 17 Change V Belt or 2 years 18 Clean Radiator Fin 19 Clean Radiator inside 20 Change Fuel Hose Oil Hose Vibration Absorbing Rubber or 2 years 21 Adjust Engi...

Page 29: ...ter wrench Supply oil and install the filler cap Caution If an oil filter wrench is not available contact our authorized distributor or service dealers Oil Filter Part No 15241 32090 Kubota 3 Clean Ch...

Page 30: ...crew the retainer ring counterclockwise and remove the cup and the gauze filter Dispose water or dirt inside the cup When dirt is adhered to the gauze filter clean the filter by compressed air Reassem...

Page 31: ...g this equipment to avoid injuries by unintentional touching cooling fan and fan belt Caution Injuries Before performing any equipment check or maintenance stop the engine and remove the engine key A...

Page 32: ...oms Possible Cause Corrective Actions Starter motor does not start 1 Battery Isolator Lever is OFF position 2 Weak Battery 3 Dead Battery 1 Turn Battery Isolator Lever to ON position 2 Recharge Batter...

Page 33: ...is selected for CC Mode 1 Turn the dial counterclockwise 2 Turn the dial counterclockwise to negative side 3 Turn to CV mode Unable to weld the Cellulose rods 1 OTHERS mode is selected for rod selecti...

Page 34: ...osed door and or intake exhaust clogging etc E03 Welding output Short Circuit Shut off the engine immediately and confirm if there is short circuit on the welding output Start the engine after resolvi...

Page 35: ...32 14 Engine Wiring Diagram...

Page 36: ...33 15 Generator Wiring Diagram...

Page 37: ...34 MEMO MEMO MEMO MEMO...

Page 38: ...35 MEMO MEMO MEMO MEMO...

Page 39: ...36...

Page 40: ...37 2011...

Reviews: