background image

Special warning:

Place the A/C on even ground and install it vertically, so as to ensure normal
operation of the compressor.

The A/C should be at least 19.7in away from surrounding objects. Keep air inlet and
outlet smooth.

Don’t use the A/C beside gasoline or any other inflammable liquid.

Don’t use spraying agent and other solvent or flammable substances near the A/C;
otherwise, its plastic may deform and electric parts may be damaged.

Power

The plug should be in good condition and can’t be damaged. Don’t replace the plug
with power lug.

In order to run the A/C, plug the power cord first, and then press the power key.

Place unit in upright position for 2 hours before turning on for first time.

Summary of Contents for SPF2-10C

Page 1: ...le Air Conditioner User s Manual Thanks for choosing this high quality portable air conditioner Please read the Manual carefully before operation In case of any problem please contact professional maintenance personnel in time ...

Page 2: ...s and Components 3 Control Panel and Remote Controller 4 Product Operation Placement and Installation 5 Operation Method 7 Clean and Maintenance Drainage Method 8 Maintenance 8 Common Failures and Diagnosis Intelligent Error Detection 10 Fuse Parameters 10 Trouble shooting 10 ...

Page 3: ...ements Any damage incurred by incorrect power isn t included in the warranty Children are not allowed to play with the A C This appliance is not intended for use by children unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Don t insert your fingers or any hard object to wind guide bar of the air outlet Don t place the A...

Page 4: ... gasoline or any other inflammable liquid Don t use spraying agent and other solvent or flammable substances near the A C otherwise its plastic may deform and electric parts may be damaged Power The plug should be in good condition and can t be damaged Don t replace the plug with power lug In order to run the A C plug the power cord first and then press the power key Place unit in upright position...

Page 5: ...ol panel 4 Air outlet louver 5 Caster 6 Remote controller 7 Air inlet R 8 Hot air outlet 9 Drainage nozzle 10 Air inlet grille 11 Exhaust duct assembly 12 Window sealing plate assembly PRODUCT INTRODUCTION MAIN PARTS AND COMPONENTS ...

Page 6: ...just timing ON OFF time press Up and Down keys simultaneously to switch Fahrenheit and Centigrade degree temperature 5 Mode key Press the key to choose cooling fan dehumidification 6 Timer key Press the key at standby mode to set ON time Press this key at ON mode to set OFF time 7 Temperature time display window This window displays the adjusted temperature and time 8 Remote controller receiving w...

Page 7: ...ven and dry place and keep it at least 19 7in away from its surrounding object Installation Screw the exhaust duct assembly in the air outlet behind the panel anticlockwise PRODUCT OPERATION PLACEMENT AND INSTALLATION 19 7in ...

Page 8: ...t to keep the exhaust duct smooth Incorrect installation will affect work of the A C Prevent the exhaust duct from sharp bending Ensure air can flow smoothly in the duct Warning The exhaust duct is designed especially for this model Don t replace or lengthen it otherwise it will result in failure Notice Max developed length of the exhaust duct is 59in It s better to shorten it while use and keep i...

Page 9: ...ts up Press Speed key to choose High Mid Low speed Temperature can t be set Dehumidification mode When pressing mode key or choosing dehumidification mode by pressing the remote controller the dehumidification indicator lamp lights up Remove the dehumidification water wedge insert water manifold place the other end of the water manifold into the water vessel or drainage passage as shown in the rig...

Page 10: ...en will display FL and the compressor stops working automatically After power off unscrew the water cover pull out the water plug to drain off water and it will become normal after being restarted Notice in order to avoid electric shock please turn off the A C and unplug before maintenance or repair CLEANING Unplug before cleaning Wipe with soft semi dry cloth Don t use chemical reagent such as be...

Page 11: ... at a shady place after cleaning SEASONAL CLEANING If the A C will not be used for a long time Pull out the water plug to drain Run the A C in fan mode for 2H till the inside is dry Turn off the A C and unplug Wash the filter screen and reassemble it Dismantle the exhaust duct and keep it properly Cover the A C with a plastic bag and place it at a dry place COMMON FAILURES AND DIAGNOSIS INTELLIGEN...

Page 12: ...ing then it will become normal Time OFF function is started The A C can be restarted 3 minutes after being turning off The A C starts frequently Direct sunlight Draw the curtain Doors and windows keep open there are lots of people or heat source in room Close doors and windows remove heat source Filter screen is very dirty Clean or replace it Air inlet or air outlet is blocked Remove the stem Big ...

Page 13: ...l appliances are disposed of in landfills or dumps hazardous substances can leak into the groundwater and get into the food chain damaging your health and well being When replacing old appliances with new ones the retailer is legally obligated to take back your old appliance for disposals at least free of charge Sales support USA03 Shinco net mailto usa03 shinco net YOAU Electric Co Ltd reserve ri...