background image

Ŷ Ŷ

1

http://www.shimaden.co.jp

ʄ

For questions, please contact 

YOUR LOCAL AGENT 

or

[email protected]

MSRS0-E53-A

Oct. 2018

Contents may be changed for improvements without notice. 
Copyright© SHIMADEN CO., LTD. All rights reserved 

SRS0 Series

                   

         

   Instruction manual        

ڦ

Preface 

Thank you for purchasing Shimaden product. Before using this product, make sure that you read thoroughly 
the precautions on safety, installation site and wiring in order to use it safely and correctly. 
This manual contains the requisite minimum information. For parameter value, initial value, and other details, 
please refer to the Digital Controller SRS1/3/4/5 Series Instruction Manual (Detailed Version). 
The Digital Controller SRS1/3/4/5 Series Instruction Manual (Detailed Version) may be downloaded free from 
the company website 

http://www.shimaden.co.jp

.

ڦ

Accessories check 

The controller has undergone sufficient quality control inspections, but you should check the specification   

 

code/appearance and make sure you have all the accessories to ensure nothing is missing or damaged. 

 

   

SRS0 

digital 

controller: 

    1 

unit 

 

   

Instruction manual (A3 size paper × 2): 

1 copy 

 

   

Unit seals:   

 

 

 

 

 

 

1 set

ڦ

Safety precautions 

Warning 

The SRS0 Series are control instruments designed for industrial use to control temperature, humidity and 
other physical values. You should either take appropriate safety measures or avoid using this product for 
control purposes where failure could have a serious effect on human life. The manufacturer shall not be liable 
for accidents that result from use without taking appropriate safety measures. 

Ɣ

 The digital controller should be used so the terminal elements in the control box, etc., are not touched by humans. 

Ɣ

 Do not remove the controller from its case or insert your fingers or electric conductors inside the case.   

Doing so could result in electric shock or accident involving death or serious injury. 

Ɣ

 Be sure to turn off power before wiring. Failure to do so could result in electric shock. 

Ɣ

 After wiring, do not touch terminal elements or other charged parts while conducting electricity.   

Failure to do so could result in electric shock. 

ڦ

Consent on use 

The warranty period for SRS0 Series is one year after the purchase. In principle, avoid use of the product 
under the following places/conditions. Should you use the controller under the following places/situations, 
be sure to use it with the proper rating and level of performance and make sure to use the controller 
correctly while taking appropriate safety measures in order to avoid accidents. 

Ɣ

 Outside 

Ɣ

 Places exposed to chemical contamination, electrical disturbance, and/or mechanical stress 

Ɣ

 Places which are not specified as an appropriate installation site in the instruction manual or catalog 

Ɣ

 When used for nuclear facilities, air facilities, space facilities, railway facilities, vehicle facilities, medical 

equipment, and facilities which are controlled by separate regulations 

Ɣ

 Facilities in which failure of the product would constitute a danger to human life or property 

Ɣ

 When used in application or facilities which require a high level of safety

Caution

If there is danger of damage to any peripheral device or equipment due to failure of the controller, you should 
take appropriate safety measures such as mounting a fuse or overheating prevention device. The manufacturer 
shall not be liable for an accident that results from use without taking appropriate safety measures. 

Ɣ

 Controller labels and alert mark 

·

Alert marks 

·

are printed on the terminal label of the case. 

You could receive an electrical shock if you 

touch charged parts. The alert mark is provided to call your attention to this danger.

Ɣ

 Provide a switch or breaker as a means of cutting off power for external power circuit connected to the power

terminal of the controller. Mount a switch or breaker near the controller where the operator can access it 
easily and label it as an electrical breaker for the controller. Use a switch or breaker that conforms to 
requirements of IEC60947. 

Ɣ

 Fuses   

The controller does not have a built-in fuse. Be sure to mount a fuse on the power circuit connected to the 
power terminal. Provide a fuse between the switch or breaker and the controller. Mount on the L side of the 
power terminal.   
  Fuse rating/characteristics: 250 V AC, 0.5 A/medium time-lagged type or time-lagged type   
  Use a fuse that conforms to requirements of IEC60127. 

Ɣ

 Voltage/current of load connected to the output terminal and EV terminal should be within the rating.   

Using voltage/current that exceeds the rating could shorten the life of the controller by raising the 
temperature and could result in equipment failure. For rating, see “11. Specifications.” 

Ɣ

 Do not apply voltage/current other than rated input to the input terminal. Doing so could shorten product life 

and lead to equipment failure. For rating, see “11. Specifications.” 

Ɣ

 Do not allow the ventilation holes to become clogged with dust, etc. Doing so could shorten the life of the 

product due to temperature rise or insulation deterioration and could result in equipment failure or fire. 

Ɣ

 Repeating endurance tests such as dielectric strength, noise resistance and surge resistance could 

negatively affect the controller. 

Ɣ

 The user should absolutely not modify or use the controller in any other way than it was intended. 

Ɣ

 It takes 30 minutes to display the correct temperature after applying power to the digital controller.   

(Therefore, turn the power on more than 30 minutes prior to the operation.) 

ڦ

Wiring 

Take the following precautions when wiring: 

Ɣ

 Wire in accordance with the “Terminal layout.” After wiring, check and make sure the wiring is correct. 

Ɣ

 Crimp-type terminals fit M3 screws. Use crimp-type terminals that are no wider than 6 mm. 

Ɣ

 For thermocouple input, use a compensating lead wire that matches the type of thermocouple. 

Ɣ

 For RTD input, resistance for lead wires should be a maximum of 10

ȍ

 per wire. All 3 wires should have the 

same resistance. 

Ɣ

 Input signal wires must not be accommodated with a strong electric circuit in the same conduit or duct. 

Ɣ

 Using shielded wiring (single point grounding) is effective for static induction noise. 

Ɣ

 Making input wiring short and twisting at regular intervals is effective for electromagnetic induction noise. 

Ɣ

 For power supply, use wiring or cable with sectional area of at least 1 mm² that offers the same or higher 

performance as 600 V vinyl insulated wiring. 

Ɣ

 Securely fasten the terminal element screw. Fastening torque: 0.5 N·m (5 kgf·cm) 

Ɣ

 If the instrument appears to be easily affected by power supply noise, use a noise filter to prevent 

malfunctioning. Mount the noise filter on the grounded panel and make the wire connection between the 
noise filter output and power line terminals of the controller as short as possible. 

ڦ

 Terminal layout 

SRS1

SRS3/SRS4/SRS5





























ڦ

 Installation site (environmental conditions) 

Caution

Do not use the controller in the following locations. Doing so could lead to equipment failure, damage or fire.

Ɣ

 Places exposed to flammable or corrosive gases, oil mist, or excessive dust that could cause insulation 

to deteriorate. 

Ɣ

 Places subject to strong vibration or impact 

Ɣ

 Places near strong electrical circuit or places subject to inductive interference 

Ɣ

 Places exposed to water dripping or direct sunlight 

Ɣ

 Places where the controller is struck directly by air from heater or air conditioner 

The controller is designed to be used under the following conditions. 
Observe the following environmental conditions: 

Ɣ

 Indoor use 

Ɣ

 Max. elevation: 2000 m 

Ɣ

 Ambient temperature: -10–50°C 

Ɣ

 Ambient humidity: Max. 90%RH, no dew condensation 

Ɣ

 Transient over voltage category: II 

Ɣ

 Pollution class: 2 (IEC 60664) 

ڦ

External dimensions and panel cutout 

Ɣ

 Cut a hole for mounting the controller in the panel by referring to external dimensions and panel cutout. 

Ɣ

 The panel thickness should be 1.0–3.5 mm. 

Ɣ

 The controller is provided with tabs for mounting. Insert as is from the front surface of the panel. 

Ɣ

 SRS0 Series controllers are designed for mounting on a panel: Be sure to mount the controller   

on a suitable panel. 

Ɣ

 If mounted in series, provide ventilation so ambient temperature does not exceed 50°C due to   

temperature rise caused by heat generation. 

SRS1

 

  

SRS3

SRS4

 

  

SRS5

Caution

In order to maintain safety and function, do not remove the case from the controller. 
If the case of the controller has to be removed for replacement/repair, contact your nearest Shimaden agent.

Min

. 6

0

 

45

 

+0

.8

 

-0

92

+0.8

-0

+0

.8

 

-0

9

+0

.8

 

-0

45

+0.6

-0

(48 × N - 3)

+1.0

-0

If mounted horizontally 

N = Number of units 

M

in. 130

 

+0

.8

 

-0

92

+0.8

-0

M

in. 130

 

(48 × N - 3)

+1.0

-0

45

+0.6

-0

+0

.6

 

-0

4

+0

.6

 

-0

Min

. 6

0

 

Unit: mm

Panel cutout 

Min. 130

Unit: mm 

Unit: mm 

Unit: mm 

Min. 130

4

9

9

If mounted horizontally 

N = Number of units 

Reviews: