water supply:
. Select a water supply hose which is a quality grade of garden hose measuring
at least 5/8” ID and no longer than 50 feet.
2 Check the water inlet strainer to ensure it is clean and free of any obstructions.
Periodic cleaning of the water strainer will help prevent pump problems. As
a strainer becomes obstructed, it restricts proper flow of water to the pump.
This can result in cavitations which will cause premature failure of pump
packings.
a. Using a screw driver, remove the screen from the water inlet.
b. Clean or replace with Mi-T-M
®
#19-0001 if necessary.
3. Connect the hoses.
a. Connect one end of the water supply hose to the water inlet of the
unit.
b. Connect the other end of the hose to your pressurized water supply.
NOTE:
Do not use a non-pressurized water supply (i.e. from a pond or well)
with this unit.
c. Connect the high pressure discharge hose to the water outlet of the
unit.
d. Securely connect the other end of the hose to the gun assembly. (A
wrench may be required on some models.)
e. Connect the wand assembly to the gun/hose assembly.
4. Follow the incoming water requirements listed below:
a. Water pressure must be a minimum of 25 pounds per square inch (PSI)
and a maximum of 00 PSI. (A typical outdoor faucet will generally
supply this PSI if turned completely “ON”.)
b. Incoming GPM must be approximately one gallon more than the outgoing
GPM stated on the pressure washer nameplate. (You can check GPM
by timing how long it takes to fill a 5 gallon container.)
c. Incoming water temperature must not exceed 25°F. Excessive pump
damage may result if the water temperature exceeds this acceptable
level.
5. Never allow the unit to operate without the incoming water line attached and
the water supply completely turned on.
cHecK water inlet strainer
installation & preparation
unloader:
factory preset:
The unloader valve on your machine is factory preset and should only be adjusted
by a trained Representative. DO NOT adjust the pressure on your own!
CAUTION
risK of unit damage!
do not oVertigHten tHe
unloader. breaKage could
result in immediate loss of
water pressure and costly
repairs.