      3) Pin Definition (9 pin)               

Pin No. 

Signal   

Name 

Function 

Level 

Connection 

with terminal 

Remarks 

GND 

Grounding of power supply 

 

Ground 

 

VCC 

Power supply DC 

+3V ~5.5V 

 

 

RxD/TTL 

Data receiving   

TTL 

TxD 

 

TxD/TTL 

Data transmitting 

TTL 

RxD 

 

SGND 

Signal 

 

 

 

A (TXD) 

A of RS-485 (TxD of RS-232) 

 

A(RxD) 

 

B (RXD) 

B of RS-485 (RxD of RS-232) 

 

B(TxD) 

SLEEP 

Sleep control   

TTL 

Sleep signal 

Low level 

valid 

TEST 

Factory testing 

 

 

 

LS-U2000 provide RS232, RS485, TTL or USB interface, please choose one when you place order. 

 

4). The Function of LED indicator 

a. The LED indicator flashes red for 0.5S when power supply on. 
b. The LED indicator blinking blue when receiving data. 
c. The LED indicator blinking Red when transmitting data. 
d. The LED indicator keeps dark when the module is in sleep mode.   
   

 

5). Parameter setting by our software 

    You  can  use  our  software  Lensen.exe  to  read  or  set  the  parameter  on  computer.  When  you 

connect RF module to PC by the testing cable, please remember to connect the DB9 as well as 
USB port to computer. 

     
    Channel Configuration: 
    Each  channel  has  its  fixed  frequency  point  which  is  per-written  to  MCU  in  factory.  The 

following  is  the  configuration  table  for  our  common  module.  If  you  need  other  frequency 
points, please tell our sales when you place order.   

Channel No. 

Frequency 

Channel No. 

Frequency 

429.0325MHz 

433.0325MHz 

430.0325MHz 

434.0325MHz 

431.0325MHz 

435.0325MHz 

432.0325MHz 

436.0325MHz 