OP-OR124RJ Four-way Return Path Optical Receiver
9. Clean and maintenance method of the optical fiber active
connector
In many times, we misjudge the decline of the optical power or the reduce of
optical receiver output level as the equipment faults, but actually it may be caused by
the incorrect connection of the optical fiber connector or the optical fiber connector
has been polluted by the dust or dirt.
Now introduce some common clean and maintenance methods of the optical
fiber active connector.
1.
Carefully pull off the optical fiber active connector from the adapter. The optical
fiber active connector should not aim at the human body or the naked eyes to
avoid accidental injury.
2.
Wash carefully with good quality lens wiping paper or medical degrease alcohol
cotton. If use the medical degrease alcohol cotton, still need to wait 1~2 minutes
after wash, let the connector surface dry in the air.
3.
The cleaned optical fiber active connector should be connected to optical power
meter to measure output optical power to affirm whether it has been cleaned up.
4.
When connect the cleaned optical fiber active connector back to adapter, should
notice to make the force appropriate to avoid the ceramic tube in the adapter
crack.
5.
If the output optical power is not normal after cleaning, should pull off the
adapter and clean the other connector. If the optical power still low after cleaning,
the adapter may be polluted, clean it. (Note: Be carefully when pull off the
adapter to avoid hurting inside fiber.
)
6.
Use the dedicated compressed air or degrease alcohol cotton bar to clean the
adapter. When use the compressed air, the muzzle of the compressed air tank
should aims at the ceramic tube of the adapter, clean the ceramic tube with
compressed air. When use degrease alcohol cotton bar, carefully insert the
alcohol cotton bar into the ceramic tube to clean. The insert direction should be
consistent, otherwise can not reach ideal cleaning effect.