4CH SD MDVR 2001 SERIES
27 / 30
5.
INSTALLATION
Power Cable Connection
For field installation, the anode (red) and cathode (black) should directly connect to car battery.
For office testing, the anode (red) and ACC (yellow) can be combined as a anode wire.
After, lock the MDVR to power on.
Server Connection
Note
: this setting is for MDVR with WIFI/3G/4G functions.
Step 1, Be ready a 3G/4G sim card inserted at MDVR
Step 2, Go to MDVR’s “terminal set”, input a phone number. Pls note this ID is a unique number
recognized by server.
Step 3, Go to MDVR’s “center set”, input phone number, input server IP and port number
accordingly.
Serial Port
The MDVR is offered with 8x alarm input and 2x alarm output.
An alarm is detected upon changes from high and low electrical level, which can link to multi
vehicle parts incl. “car brake, steering, on/off switch, alarm button” etc. For example, when
braking vane is treaded, MDVR detects a high electrical level signal and output an alarm depending
on setting, otherwise it’
s detected as low electrical level.