background image

3

PARTS LIST

Fittings Bolt set M10

Nut Washer Black

Cap

T25

T50

AB1210

M10 x 60mm

25 mm 

Tech 

screw

50 mm 

Tech 

screw

M10/12 x 10mm 

Concrete Bolt

Pack A

30

30

60

60

72

30

8

Required

14

14

28

28

68

30

8

Spare

16

16

32

32

4

0

0

Image

ITEM 

NO.

PART 

NO.

DESCRIPTION DIMENSION

IMAGE

QTY.

1

S1

Frame

2000x1035

6

2

P1

Post

106x110x40

1

3

ST1

Roof Tie

Trim To 2195

1

4

CB1

Bracket

2000x1035

7

5

JF1

Bracket

110x110x40

6

6

FT1

Foot Bracket 109x100x40

3

7

FT3

Foot Bracket 109x100x80

5

8

RB1

Bracket

110x46

8

9

R2

Rafter

2200x40x40

3

10

SS

Sealing Strip

110x46

2 ROLLS

11

PCE2

Roof Panel

2205x1050

2

12

RC2

Roof Strip

2060x40x40

3

13

2MD

Roof Edge 

Trim

Trim To Fit

3

14

EC40

Plastic end 

Cap

2205x1030

9

Summary of Contents for SR1554

Page 1: ...Assembly Instructions Shelter type SR1554 SR1554 03 260916 UK Email Sales shelters4less co uk Web www shelters4less co uk Tel 0800 160 1002 ...

Page 2: ...EXPLODED VIEW AND TOOLS 11 13 12 2 3 8 9 4 7 6 1 5 10 2 Tools required Drill Screwdriver Mallet Hack saw Tools included Spanner Torx bit ...

Page 3: ...NO DESCRIPTION DIMENSION IMAGE QTY 1 S1 Frame 2000x1035 6 2 P1 Post 106x110x40 1 3 ST1 Roof Tie Trim To 2195 1 4 CB1 Bracket 2000x1035 7 5 JF1 Bracket 110x110x40 6 6 FT1 Foot Bracket 109x100x40 3 7 FT3 Foot Bracket 109x100x80 5 8 RB1 Bracket 110x46 8 9 R2 Rafter 2200x40x40 3 10 SS Sealing Strip 110x46 2 ROLLS 11 PCE2 Roof Panel 2205x1050 2 12 RC2 Roof Strip 2060x40x40 3 13 2MD Roof Edge Trim Trim ...

Page 4: ...are aligned correctly Step 1 Assemble S1 frames to make up the main structure using CB1 brackets in the corners and JF1 brackets on straight joints Then attach P1 Post using one JF1 bracket Then attach ST1 Tie bar using a JF1 bracket and one CB1 bracket GENERAL NOTE THE 50 mm TECH SCREWS ARE FOR FIXING ROOF STRIPS RC ONLY ...

Page 5: ...1035 FRONT VIEW R2 RB1 FT1 FT2 Step 2 Move shelter in to its final position make sure everything is square and secure to the floor using FT1 and FT3 foot brackets Attach R2 roof rafters using RB1 brackets 5 ...

Page 6: ...S sealing strips to the rafters two for cental rafter and line up the PCE2 roof panels to the outside of the shelter leaving a gap between them Apply more sealing strips to the top of the roof panel directly above the first strips 6 ...

Page 7: ...D2 Step 4 Apply RC2 strips on top of the panels and use 50mm Tech screws to secure them in place Then clip on the 2MD edge trim to the bottom of the roof panels Then fit the Black plastic caps on exposed nuts and bolts Fit the square plastic end caps to any open ends of box sections 7 ...

Page 8: ...1044 50 1035 1044 50 1035 1044 50 1136 50 1035 995 2181 2181 Ground anchor positions and overall size Suggested concrete base size 200mm oversized on all four sides Scale 1 15 8 ...

Page 9: ...NOTES 9 ...

Page 10: ...NOTES 10 ...

Page 11: ...NOTES 11 ...

Page 12: ...ularly with soapy water Ensure all fittings are tight for example after a big storm Touch up any exposed metal should it get scratched CONTACT DETAILS Email Sales shelter4less co uk Web www shelters4less co uk Tel 0800 160 1002 Shelters4Less Unit 3 2 Landsdowne Crescent Bournemouth BH1 1SA All Parts and Fixings checked by Print Name Signature ...

Reviews: