11.3. AI Setup
All AI settings must be
configured on the surface
before a dive, since the
System Setup menu is not
accessible during a dive�
AI Mode
AI Mode is used to easily enable or disable AI�
AI Mode Setting Description
Off
AI sub-system is completely powered
down and consumes no power�
On
AI is enabled� When on, AI increases
power consumption by about 10%�
Units
Choices are bar or psi�
TX Setup
The Transmitter setup (TX
Setup) menu is used to set up
transmitters� Currently active
transmitters are shown next
to TX Setup in the top level AI
menu�
Up to 4 transmitters can
be configured in this menu�
Select a transmitter to modify
its attributes�
Transmitter On/ Off
Turn off transmitters that are
not currently in use to save
battery power�
Tank Setup
Navigate over to and select a
transmitter’s serial number in
the transmitter setup menu
to enter the tank set up menu
for that transmitter�
Serial Number Setup
Every transmitter has a
unique 6-digit serial number
.
This number is etched onto
the side of the transmitter�
Enter the serial number to
pair the transmitter to T1�
This number only needs to be
entered once� Like all settings,
it is stored in permanent
memory� Transmitter settings
are saved across all dive
modes�
Set AI Mode to OFF when AI not in use
Leaving AI enabled when not in use will negatively
impact battery life when the computer is turned on�
When a paired transmitter is not communicating, the
Petrel 3 goes into a higher power scan state� This
increases power consumption to about 25% higher
than with AI off� Once communications are established,
power drops to about 10% higher than with AI off�
Note, AI is never active when the computer is off� There
is no need to turn AI off when the computer is turned
off�
AI Mode
Units
Tx Setup
GTR Mode
On
Bar
T1 T2
SM:T1+T2
Next
Edit
AI Setup
SM Switch
21
Bar
#
On
Next
Edit
Transmitters
Serial
T1
On
285817
T2
On
005752
T3
Off
000000
T4
Off
000000
Setup
#
On
Change
Next
Transmitters
Serial
T1
On
285817
T2
On
005752
T3
Off
000000
T4
Off
000000
T1 Serial#
Rated
Reserve
Rename
Unpair
285817
207
Bar
048
Bar
T1
Next
Edit
Tank Setup