Seite 25 von 134
TRACKING AND FIXING PROBLEMS
Before contacting our customer hotline/service centre, please check whether the error can be
rectified using the instructions below.
PROBLEM
POSSIBLE CAUSE
SOLUTION
The air cooler does not
switch on.
You are using the wrong button.
You can switch on the appliance
with the
button either on the
remote control or directly on the
appliance.
Power failure
Wait for the power supply to be
restored.
The appliance is not connected to
the power supply.
Connect/plug the appliance to the
power supply and wait for a
minimum of 30 mins!
The remote control battery is flat.
Please replace the battery.
The air cooler works only
for a short amount of time.
The water tank is empty.
Fill the water tank.
Something is blocking the air
outlet.
Check and remove all obstacles
that are blocking the air supply.
During operation, an
unpleasant odour is
emerging from the room.
The air filter or water tank is dirty.
Clean the air filter(s) and/or water
tank in accordance with the
description.
The appliance is very loud.
The floor that the air cooler is
located on is not level.
Place the air cooler in a different
location.
Technical information
Nominal voltage
220 V ~ 240 V
Frequency
50 Hz
Rated power input
65 W
Water tank capacity
20 L
Description
Symbol
Value
Unit
Maximum air velocity
V
9.5
m/s
Air circulation
SV
580
(m³/h) W
Fan sound power level
LWA
61
dB(A)
Max. evaporative capacity
AL
400
ml/h
Consumption in standby mode
PSB
0.4
W
Dimensions
Product dimensions:
370 x 320 x 740 mm
Weight:
7.1 kg
Contact addresses for more information and
Serviceline:
Schuss Home Electronic GmbH
Scheringgasse 3, A-1140 Vienna, Austria
Tel: +43 (1) 97 0 21 – 0
Serviceline: +43 (1) 97 0 21 – 502
www.she.at
FB no.: 236974 t / FB court: Vienna