XR-30S/XR-30X/XG-F210X
4 – 3
* Writing a software program (before main PWB is mounted)
Use the DLP Composer Lite Ver. 4.2 to download the firmware.
After writing the specified version of firmware to the PWB using the RS232C cable, check the version of the written firmware.
If no software program is written, all three LEDs light up in the chassis inspection process.
Calling and quitting the process mode with the control keys on this model.
* Although it is possible for the process OUT to exit using the process menu, the IN/OUT toggle command is also available considering the existing
specification.
1) Calling and quitting
With the menu not displayed, press the "ENTER", "ENTER", "VOL+", "VOL-", "ENTER", "ENTER" and "MENU" keys on the remote control or on
the main unit.
2) Others
Press the S2551 process key (toggle) on the main PWB to call and quit the process menu.
NOTE: When adjusting in the process mode, set a signal with a vertical frequency of 60 Hz or no signal. (May not be properly adjusted with other sig-
nals.)
Resetting the lamp timer for this model
1) Resetting procedure
In Stand-by, run this command to clear the operating time of the lamp to 0 and turn on the power.
Press and hold "
", "ENTER", and "MENU", and then press the "STANDBY/ON" key of the set.
Forced disabling of the System-Lock of this model
1) Disabling procedure
With System-Lock input window onscreen, press the "MENU", "ENTER", "ENTER", "MENU", "ENTER", "ENTER" and "MENU" keys, in this order,
on the remote controller.
16
RS232C operation check
1. Connect the unit and a PC with the
RS232C cable.
1. Send a command from the PC, and check it func-
tions correctly.
17
Model name and version check
1. Select the following group.
Group : INFO/VERSION.
1. The model name appears in the MODEL field, and
the firmware version in the VERSION field. Check
that they are correct.
18
Setup guide screen check
1. Turn on the power after making the setup
guide display ON setting or factory setting
(SS4, etc.).
1. Check that the 4-split screen is displayed correctly
and the display contents are correct.
19
Delivery settings
1. Make the following settings.
No.
Adjusting point
Adjusting conditions
Adjusting procedure
Destination
Process
Remote control
adjustment
adjustment
USA
SS4
Factory setting at 4
China
SS6
Factory setting at 6
Others
SS3
Factory setting at 3
Summary of Contents for XG-F210X
Page 39: ...XR 30S XR 30X XG F210X 5 2 IC2263 IC2232 and peripheral circuits ...
Page 51: ...XR 30S XR 30X XG F210X 6 4 11 13 12 14 15 16 18 19 17 ...
Page 53: ...XR 30S XR 30X XG F210X 7 2 11 13 12 14 15 16 18 19 17 ...
Page 55: ...XR 30S XR 30X XG F210X 7 4 11 13 12 14 15 16 18 19 17 ...
Page 56: ...XR 30S XR 30X XG F210X 7 5 1 2 3 4 5 6 7 9 10 8 J A B C D E F G H I MAIN Unit Side B ...
Page 57: ...XR 30S XR 30X XG F210X 7 6 11 13 12 14 15 16 18 19 17 ...
Page 59: ...XR 30S XR 30X XG F210X 7 8 11 13 12 14 15 16 18 19 17 ...
Page 63: ...XR 30S XR 30X XG F210X 7 12 11 13 12 14 15 16 18 19 17 ...
Page 64: ...XR 30S XR 30X XG F210X 7 13 1 2 3 4 5 6 7 9 10 8 J A B C D E F G H I BALLAST POWER Unit Sid B ...
Page 65: ...XR 30S XR 30X XG F210X 7 14 11 13 12 14 15 16 18 19 17 ...
Page 75: ...XR 30S XR 30X XG F210X 9 3 11 13 12 14 15 16 18 19 17 ...
Page 76: ...XR 30S XR 30X XG F210X 9 4 1 2 3 4 5 6 7 9 10 8 J A B C D E F G H I MAIN Unit 1 XG F210X ...
Page 77: ...XR 30S XR 30X XG F210X 9 5 11 13 12 14 15 16 18 19 17 ...
Page 78: ...XR 30S XR 30X XG F210X 9 6 1 2 3 4 5 6 7 9 10 8 J A B C D E F G H I MAIN Unit 2 XR 30S XR 30X ...
Page 79: ...XR 30S XR 30X XG F210X 9 7 11 13 12 14 15 16 18 19 17 ...
Page 80: ...XR 30S XR 30X XG F210X 9 8 1 2 3 4 5 6 7 9 10 8 J A B C D E F G H I MAIN Unit 2 XG F210X ...
Page 81: ...XR 30S XR 30X XG F210X 9 9 11 13 12 14 15 16 18 19 17 ...
Page 82: ...XR 30S XR 30X XG F210X 9 10 1 2 3 4 5 6 7 9 10 8 J A B C D E F G H I MAIN Unit 3 ...
Page 83: ...XR 30S XR 30X XG F210X 9 11 11 13 12 14 15 16 18 19 17 ...
Page 84: ...XR 30S XR 30X XG F210X 9 12 1 2 3 4 5 6 7 9 10 8 J A B C D E F G H I MAIN Unit 4 ...
Page 85: ...XR 30S XR 30X XG F210X 9 13 11 13 12 14 15 16 18 19 17 ...
Page 86: ...XR 30S XR 30X XG F210X 9 14 1 2 3 4 5 6 7 9 10 8 J A B C D E F G H I MAIN Unit 5 ...
Page 87: ...XR 30S XR 30X XG F210X 9 15 11 13 12 14 15 16 18 19 17 ...
Page 88: ...XR 30S XR 30X XG F210X 9 16 1 2 3 4 5 6 7 9 10 8 J A B C D E F G H I MAIN Unit 6 ...
Page 89: ...XR 30S XR 30X XG F210X 9 17 11 13 12 14 15 16 18 19 17 ...
Page 90: ...XR 30S XR 30X XG F210X 9 18 1 2 3 4 5 6 7 9 10 8 J A B C D E F G H I MAIN Unit 7 XR 30S ...
Page 91: ...XR 30S XR 30X XG F210X 9 19 11 13 12 14 15 16 18 19 17 ...
Page 93: ...XR 30S XR 30X XG F210X 9 21 11 13 12 14 15 16 18 19 17 ...
Page 94: ...XR 30S XR 30X XG F210X 9 22 1 2 3 4 5 6 7 9 10 8 J A B C D E F G H I MAIN Unit 8 ...
Page 95: ...XR 30S XR 30X XG F210X 9 23 11 13 12 14 15 16 18 19 17 ...
Page 96: ...XR 30S XR 30X XG F210X 9 24 1 2 3 4 5 6 7 9 10 8 J A B C D E F G H I MAIN Unit 9 ...
Page 97: ...XR 30S XR 30X XG F210X 9 25 11 13 12 14 15 16 18 19 17 ...
Page 98: ...XR 30S XR 30X XG F210X 9 26 1 2 3 4 5 6 7 9 10 8 J A B C D E F G H I DMD Unit 1 ...
Page 99: ...XR 30S XR 30X XG F210X 9 27 11 13 12 14 15 16 18 19 17 ...
Page 100: ...XR 30S XR 30X XG F210X 9 28 1 2 3 4 5 6 7 9 10 8 J A B C D E F G H I DMD Unit 2 ...
Page 101: ...XR 30S XR 30X XG F210X 9 29 11 13 12 14 15 16 18 19 17 ...
Page 102: ...XR 30S XR 30X XG F210X 9 30 1 2 3 4 5 6 7 9 10 8 J A B C D E F G H I DMD Unit 3 ...
Page 103: ...XR 30S XR 30X XG F210X 9 31 11 13 12 14 15 16 18 19 17 ...
Page 104: ...XR 30S XR 30X XG F210X 9 32 1 2 3 4 5 6 7 9 10 8 J A B C D E F G H I BALLAST POWER Unit ...
Page 106: ...XR 30S XR 30X XG F210X 9 34 1 2 3 4 5 6 7 9 10 8 J A B C D E F G H I BALLAST CONTROL Unit ...
Page 108: ...XR 30S XR 30X XG F210X 9 36 1 2 3 4 5 6 7 9 10 8 J A B C D E F G H I PHOTO SENSOR Unit ...
Page 109: ...XR 30S XR 30X XG F210X 9 37 11 13 12 14 15 16 18 19 17 ...
Page 110: ...XR 30S XR 30X XG F210X 9 38 1 2 3 4 5 6 7 9 10 8 J A B C D E F G H I R C RECEIVER Unit ...
Page 111: ...XR 30S XR 30X XG F210X 9 39 11 13 12 14 15 16 18 19 17 ...
Page 112: ...XR 30S XR 30X XG F210X 9 40 MEMO ...