– 57 –
SD-AT50H
IC701 RH-iX0564AWZZ: System Microcomputer (IX0564AW)
1
D3
A/D_RESET
Output
Output of 1 bit AMP
∆∑
IC reset control.
“H” output : normal operation, reset when switching from “L” to “H”.
2*
D4
N.C.
Output
Open terminal. “L” is output, PWB is open.
3
D5
SP_RLY
Output
Speaker relay output. (For all the speakers)
“H” output : relay ON, electric conduction, “L” output : relay OFF
4
D6/CNTR0
BASS_SW
Output
Output for controlling the gain of SUBWOOFER amp.
“H” output : BASS OFF, “L” output : BASS ON
5
D7/CNTR1
AC_DETECT
Input
Power failure check with the voltage after the AC rectification.
Normal : “L”, power failure detection when switching from “L” to “H”.
6
P20/SCK
AMP_CLK
Input
Clock input for communication with the system microcomputer.
Serial auto send/receive.
7
P21/SOUT
AMP_SIN
Output
Data output to the system microcomputer. Serial auto send/receive.
8
P22/SIN
AMP_SOUT
Input
Data input from the system microcomputer. Serial auto send/receive.
9
RESET
RESET
Input
Reset input for this microcomputer. Active “L”.
10
CNVSS
CNVSS
Input
0 V (GND).
11
XOUT
XOUT
Output
Reference oscillation output for this microcomputer.
2 MHz ceralcok connection.
12
XIN
XIN
Input
Reference oscillation input for this microcomputer.
2 MHz ceralcok connection.
13
VSS
VSS
Input
GND terminal.
14
VDD
VDD
Input
Positive power supply terminal.
15
VDCE
VDCE
Input
Control of the operation and stop of voltage drop detect circuit.
Used in the stop status (connected to GND).
16
P30/INT0
AMP_INT
Output
Communication request signal to the system microcomputer.
Request when switching from “H” to “L”.
17
P31/INT1
POWER_ON
Input
SW input for POWER ON/OFF test mode.
“H” : normal status, “L” : TEST mode ON/OFF
18
AIN0/CMP0-
+B_CHECK
Input
Power rise monitoring input.
Decision of the reset timing of 1 bit AMP.
19
AIN1/CMP0+
PROTECT
Input
A/D import, system abnormality detect input.
20
AIN2/CMP1-
FAN_CHK
Input
A/D import, FAN motor rotation detect input.
21
AIN3/CMP1+
FAN_LOCK
Input
A/D import, FAN motor lock detect input.
22
P00
F_S_MUTE
Output
Front speaker S-MUTE output.
“H” output : MUTE-ON, “L” output : MUTE-OFF.
23
P01
C_S_MUTE
Output
Center speaker S-MUTE output.
“H” output : MUTE-ON, “L” output : MUTE-OFF.
24
P02
S_S_MUTE
Output
Surround speaker S-MUTE output.
“H” output : MUTE-ON, “L” output : MUTE-OFF.
25
P03
W_S_MUTE
Output
Subwoofer speaker S-MUTE output.
“H” output : MUTE-ON, “L” output : MUTE-OFF.
26
P10
AMP_STB
Input
Communication request signal from the system microcomputer.
Request when switching from “H” to “L”.
27
P11
—
Input
PULL_UP
28
P12
SYS_STOP
Input
Power failure detect input. This microcomputer switches to the backup mode.
Normal : “H”, power failure detection when switching from “H” to “L”.
29
P13
OFF_SET
Input
Abnormality detection output of 1 bit AMP
∆∑
IC output offset voltage.
L : abnormal
30
D0
UNSW_CHK
Input
Power rise timing control. The power is not risen in “L”.
31
D1
POWER
Output
Output of power supply control.
“L” output : POWER ON, “H” output : POWER OFF.
32
D2
-B_CONT
Output
Control output for - B power supply control relay of 1 bit AMP section.
“L” output : relay ON, -B supply “H” output : relay OFF
Terminal Name
Pin No.
Input/Output
Function
In this unit, the terminal with asterisk mark (*) is (open) terminal which is not connected to the outside.
Port Name