3-7
3.4.3 (For TPR-2000H)
Motor Part Name
Rated Power Capacity
Maximum Initiate Power
Main Motor
5.625kw
15.75kw
Elevating Motor
2.25kw
6.3kw
Hydraulic Motor
0.75kw
2.1kw
Coolant Pump Motor
0.1kw
0.28kw
Total Rated Power Capacity:
(5.625kw+2.25kw+0.75kw+0.1kw)=8.725kw…………….(1)
Maximum Total Initiate Power Capacity:
(15.75kw+6.3kw+2.1kw+0.28kw)=24.43kw…………….(2)
Transformer Rated Output Power Capacity for Control Circuits
Model
Item
100VA
Input
AC400V
±
10% 1
∅
Power Supply
Output
AC240V
±
10% 1
∅
Ambient Temperature
0°C To 55°C
S=KVA
P=KW
Pf
×
n = 0.75 (Correction Factors)
S=
KW
Pf
×
n(0.75)
P=
8.725Kw
0.75
=11.633KVA………………….. (1)
P=
24.43Kw
0.75
=32.573KVA.………………….. (2)
Power Equipment Capacity=
11.32.573KVA
2
=22.193KVA