R-875/885 -
33
Choke Cover
Putty Knife
Door Frame
Pin
PIN
Lower
Oven Hinge
Upper
Oven Hinge
Lower
Oven
Hinge
Choke Cover
Slit Choke
Door Panel
Door Sub
Assembly
COMPONENT REPLACEMENT AND ADJUSTMENT PROCEDURE
6. Lift the door upwards.
7. Now, door sub assembly is free from oven cavity.
8. Remove the four (4) screws holding the door panel to
the door frame.
9. Now, door panel is free.
10.Slide latch head upward and remove it from door
frame with releasing latch spring from door frame and
latch head.
11.Now, latch head and latch spring are free.
12.Remove the glass stopper from the door frame.
13.Slide the front door glass leftwards and then slide
upwards to release the tabs holding it.
14.Now, the front door glass is free
RE-INSTALL
1. Re-install the front door glass to the door frame as
follows.
a) Insert the upper edge of the front door glass into the
four (4) tabs of the door frame.
b) Slide the front door glass downwards and insert the
lower edge of the front door glass into the four (4)
tabs of the door frame.
c) Slide the front door glass rightwards and insert the
right edge of the front door glass into the three (3)
tab of the door frame.
2. Re-install the glass stopper to the door frame.
3. Re-install the latch spring to the latch head. Re-install
the latch spring to the door frame. Re-install latch head
to door frame.
4. Re-install door panel to door frame by fitting two (2)
tabs of glass stopper to two (2) holes of door panel.
5. Hold the door panel to the door frame with four (4)
screws.
6. Located door panel hinge pins into cavity hinge loca-
tion hole.
7. Re-install choke cover to door panel by clipping into
position.
Figure C-7. Door Disassembly
Note: After any service to the door;
(A) Make sure that the monitor switch, monitored
latch switch and stop switch are operating prop-
erly. (Refer to chapter "Test Procedures".).
(B) An approved microwave survey meter should be
used to assure compliance with proper micro-
wave radiation emission limitation standards.
(Refer to Microwave Measurement Procedure.)
After any service, make sure of the following :
1. Door latch heads smoothly catch latch hook through
latch holes and that latch head goes through centre of
latch hole.
2. Deviation of door alignment from horizontal line of
cavity face plate is to be less than 1.0mm.
3. Door is positioned with its face pressed toward cavity
face plate.
4. Check for microwave leakage around door with an
approved microwave survey meter. (Refer to Micro-
wave Measurement Procedure.)
Note:
The door on a microwave oven is designed to act
as an electronic seal preventing the leakage of
microwave energy from oven cavity during cook
cycle. This function does not require that door be
air-tight, moisture (condensation)-tight or light-
tight. Therefore, occasional appearance of mois-
ture, light or sensing of gentle warm air movement
around oven door is not abnormal and do not of
themselves, indicate a leakage of microwave en-
ergy from oven cavity.
Figure C-8. Door Replacement