16
R-4A56
TOUCH CONTROL PANEL ASSEMBLY
OUTLINE OF TOIUCH CONTROL PANEL
3) Synchronizing Signal Circuit
This power source synchronizing signal is available in
order to compose a basic standard time in the clock
circuit. It accompanies a very small error because it
works on commercial frequency.
4) ACL Circuit
A circuit to generate a signals which resets the LSI to the
initial state when power is supplied.
5) Buzzer Circuit
The buzzer is responsive to signals from the LSI to emit
noticing sounds (key touch sound and completion sound).
6) Door Sensing Switch
A switch to “tell” the LSI if the door is open or closed.
7) Relay Circuit
To drive the magnetron, fan motor, turntable motor and
light the oven lamp.
8) Indicator Circuit
Indicator element is a Fluorescent Display.
Basically, a Fluorescent Display is triode having a
cathode, a grid and an anode. Usually, the cathode of a
Fluorescent Display is directly heated and the filament
serves as cathode.
The Fluorescent Display has 6-digits, 13-segments are
used for displaying figures.
The touch control section consists of the following unit as
shown in the touch control panel circuit.
(1) Key Unit
(2) Control Unit
The principal functions of these units and the signals com-
municated among them are explained below.
Key Unit
The key unit is composed of a matrix, signals generated in
the LSI are sent to the key unit through R0
0
-R0
3
,R1
0
-R1
3.
When a key pad is touched, a signal is completed through
the key unit and passed back to the LSI through R2
3
,R3
0
-
R3
2
to perform the function that was requested.
Control Unit
Control unit consists of LSI, power source circuit, synchro-
nizing signal circuit, ACL circuit, buzzer circuit and indicator
circuit.
1) LSI
This LSI controls the key strobe signal, relay driving
signal for oven function and indicator signal.
2) Power Source Circuit
This circuit generates voltages necessary in the control
unit.
Symbol
Voltage
Application
VC
-5V
LSI(IC1)
VP
-29V
Fluorescent display tube : Grid
and anode voltage
VF1
3Vac
Filament of fluorescent display
tube
VF2
(VF1 to VF2 voltage)
Summary of Contents for R-4A56