R-380A
17
DESCRIPTION OF LSI
LSI(IZA778DR):
The I/O signal of the LSI(IZA778DR) is detailed in the following table.
Pin No.
Signal
I/O
Description
A
B
0.12 sec.
2.4 sec.
H : GND
L : -5V
H : GND
L : -5V
1
C1
IN
Terminal not used.
2
VL1
IN
Power source voltage input terminal.
Standard voltage for LCD.
3-6
AN7-AN4
IN
Terminal to change cooking constant according to the Model.
By using the A/D converter contained in the LSI, DC voltage in accordance with the
Model in operation is applied to set up its cooking constant.
7
AN3
OUT
Terminal not used.
8
AIN2
IN
To input signal which communicates the door open/close information to LSI.
Door closed; "H" level signal (0V).
Door opened; "L" level signal (-5V).
9
AN1
IN
AH sensor input.
This input is an analog input terminal from the AH sensor circuit, and connected
the A/D converter built into the LSI.
10
AN0
IN
Used for initial balancing of the bridge circuit (absolute humidity sensor). This input
is an analog input terminal from the AH sensor circuit, and connected to the A/D
converter built into the LSI.
11-13
P57-P55
OUT
Terminal not used.
14
P54
OUT
Signal to sound buzzer (2.0kHz).
A: key touch sound.
B: Completion sound.
15-18
P53-P50
OUT
Terminal not used.
19-23
P47-P43
OUT
Used for initial balancing of the bridge circuit (absolute humidity sensor).
24
INT0
IN
Signal synchronized with commercial power source frequency.
This is the basic timing for time process-
ing of LSI.
25-26
P41-P40
OUT
Terminal not used.
27
P77
IN
Signal coming from touch key.
When either G12 line on key matrix is touched, a corresponding signal out of P20
- P27 will be input into P77. When no key is touched, the signal is held at "H" level.
28
P76
IN
Signal similar to R77.
When either G11 line on key matrix is touched, a corresponding signal will be input into R76.
29
P75
IN
Signal similar to R77.
When either G10 line on key matrix is touched, a corresponding signal will be input into R75.
30
P74
IN
Signal similar to R77.
When either G9 line on key matrix is touched, a corresponding signal will be input into R74.
31
P73
OUT
Oven lamp, fan motor and turntable motor driving signal.
To turn on and off the shut-off relay (RY1).
The square waveform voltage is delivered
to the relay RY1 driving circuit and RY2
control circuit.
32
P72
OUT
Magnetron high-voltage circuit driving signal.
To turn on and off the cook relay
(RY2). The signals holds "L" level
during microwave cooking and "H"
level while not cooking. In other cook-
ing modes (variable cooking) the sig-
nal turns to "H" level and "L" level in
repetition according to the power level.
33
P71
OUT
Terminal not used.
34
P70
IN
Connected to VC.
35
RESET
IN
Auto clear terminal.
Signal is input to reset the LSI to the initial state when power is supplied.
Temporarily set to "L" level the moment power is supplied, at this time the LSI is
reset. Thereafter set at "H" level.
20.0 msec.
H : GND
L : -5V
20.0 msec.
During cooking
H : GND
L : -5V
P-HI
H : GND
L : -5V
H : GND
L : -5V
P-70
ON
ON
OFF
OFF
OFF
24 sec.
8 sec.