21
R-320BB
R-320BK
R-320BW
LSI(IZA865DR)
The I/O signal of the LSI(IZA865DR) is detailed in the following table.
Pin No.
Signal
I/O
Description
P-HI
H : GND
L : -5V
H : GND
L : -5V
P-70
ON
ON
OFF
OFF
OFF
24 sec.
8 sec.
A
B
0.1 sec.
2.0 sec.
H : GND
L : -5V
H : GND
L : -5V
16.7 msec.
During cooking
H : GND
L : -5V
16.7 msec.
H : GND
L : -5V
1-2
VL2-VL1
IN
Power source voltage input terminal.
Standard voltage for LCD.
3-6
AN7-AN4
IN
Terminal to change cooking input according to the Model.
By using the A/D converter contained in the LSI, DC voltage in accordance with the Model
in operation is applied to set up its cooking constant.
7
AN3
OUT
Terminal not used.
8
AN2
IN
To input signal which communicates the door open/close information to LSI.
Door close "H" level signal (0V). Door open "L" level signal (-5V).
9
AN1
IN
AH sensor input.
This input is an analog input terminal from the AH sensor circuit, and connected to the A/D
converter built into the LSI.
10
AN0
IN
Used for initial balancing of the bridge circuit (absolute humidity sensor). This input is an
analog input terminal from the AH sensor circuit, and connected to the A/D converter built
into the LSI.
11-13
P57-P55
OUT
Used for initial balancing of the bridge circuit (absolute humidity sensor).
14
P54
OUT
Signal to sound buzzer (2.0 kHz).
A: key touch sound.
B: Completion sound.
15
P53
OUT
Used for initial balancing of the bridge circuit (absolute humidity sensor).
16
P52
OUT
Oven lamp, fan motor and turntable motor driving signal
To turn on and off shut off relay (RY1). The
square waveform voltage is delivered to the
RY1 driving circuit and RY2 control circuit.
17
P51
OUT
Used for initial balancing of the bridge circuit (absolute humidity sensor).
18
P50
OUT
Terminal not used.
19
P47
OUT
Magnetron high-voltage circuit driving signal.
To turn on and off the cook relay (RY2). The
signals holds "L" level during microwave cook-
ing and "H" level while not cooking. In other
cooking modes (variable cooking) the signal
turns to "H" level and "L" level in repetition
according to the power level.
(ON and OFF times for other power level.)
20
P46
IN
Signal coming from touch key.
When either G12 line on key matrix is touched, a corresponding signal out of P20 - P27 will
be input into P46. When no key is touched, the signal is held at "H" level.
21
P45
IN
Signal similar to P46.
When either G11 line on key matrix is touched, a corresponding signal will be input into P45.
22
P44
IN
Signal similar to P46.
When either G10 line on key matrix is touched, a corresponding signal will be input into P44.
23
P43
IN
Signal similar to P46.
When either G9 line on key matrix is touched, a corresponding signal will be input into P43.
24
INT0
IN
Signal synchronized with commercial power source frequency.
This is the basic timing for time processing of LSI.