4
R-305BW
R-309BW
ITEM
DESCRIPTION
Power Requirements
120 Volts / 12 Amperes for R-305BW, 13 Amperes for R-309BW
60 Hertz
Single phase, 3 wire grounded
Power Output
900 watts[R-305BW] / 1000 watts[R-309BW] (IEC-705 TEST PROCEDURE)
Operating frequency of 2450MHz
Case Dimensions
Width 20-1/2"
Height 11-7/8"
Depth 15-7/8"
Cooking Cavity Dimensions
Width 13-3/4"
Height 8-3/8"
1.0 Cubic Feet
Depth 14-7/8"
Control Complement
Touch Control System
Clock ( 1:00 - 12:59 )
Timer (0 - 99 min. 99 seconds)
Microwave Power for Variable Cooking
Repetition Rate;
P-HI .................................................. Full power throughout the cooking time
P-90 .................................................................... approx. 90% of Full Power
P-80 .................................................................... approx. 80% of Full Power
P-70 .................................................................... approx. 70% of Full Power
P-60 .................................................................... approx. 60% of Full Power
P-50 .................................................................... approx. 50% of Full Power
P-40 ..................................................................... approx. 40% of Full Power
P-30 ..................................................................... approx. 30% of Full Power
P-20 .................................................................... approx. 20% of Full Power
P-10 ..................................................................... approx. 10% of Full Power
P-0 .................................................... No power throughout the cooking time
INSTANT START pads
COMPU DEFROST pad
Number selection pads
POWER LEVEL pad
TIMER/CLOCK pad
STOP/CLEAR pad
START/MINUTE PLUS pad
Oven Cavity Light
Yes
Safety Standard
UL Listed FCC Authorized
DHHS Rules, CFR, Title 21, Chapter 1, Subchapter J
SPECIFICATION
GENERAL INFORMATION
GROUNDING INSTRUCTIONS
This oven is equipped with a three prong grounding plug. It must be plugged into a wall receptacle that is properly installed
and grounded in accordance with the National Electrical Code and local codes and ordinances.
In the event of an electrical short circuit, grounding reduces the risk of electric shock by providing an escape wire for the
electric current.
WARNING: Improper use of the grounding plug can result in a risk of electric shock.
Electrical Requirements
The electrical requirements are a 115 -120 volt 60 Hz, AC only,
15 or 20 amp. fused electrical supply. It is recommended that a separate circuit serving only this appliance be provided. When
installing this appliance, observe all applicable codes and ordinances.