background image

R-230HK

PRECAUTIONS TO BE OBSERVED BEFORE AND
DURING SERVICING TO AVOID POSSIBLE
EXPOSURE TO EXCESSIVE MICROWAVE
ENERGY

(a) Do not operate or allow the oven to be operated with the door open.
(b) Make the following safety checks on all ovens to be serviced before activating the magnetron or other

microwave source, and make repairs as necessary: (1) interlock operation, (2) proper door closing, (3)
seal and sealing surfaces (arcing, wear, and other damage), (4) damage to or loosening of hinges and
latches, (5) evidence of dropping or abuse.

(c) Before turning on microwave power for any service test or inspection within the microwave generating

compartments, check the magnetron, wave guide or transmission line, and cavity for proper alignment,
integrity, and connections.

(d) Any defective or misadjusted components in the interlock, monitor, door seal, and microwave

generation and transmission systems shall be repaired, replaced, or adjusted by procedures described
in this manual before the oven is released to the owner.

(e) A microwave leakage check to verify compliance with the Federal Performance Standard should be

performed on each oven prior to release to the owner.

BEFORE SERVICING

Before servicing an operative unit, perform a microwave emission check as per the Microwave
Measurement Procedure outlined in this service manual.
If microwave emissions level is in excess of the specified limit, contact SHARP ELECTRONICS
CORPORATION immediately  @1-800-237-4277.

If the unit operates with the door open, service person should 1) tell the user not to operate the oven
and 2) contact SHARP ELECTRONICS CORPORATION and Food and Drug Administration's
Center for Devices and Radiological Health immediately.

Service personnel should inform SHARP ELECTRONICS CORPORATION of any certified unit
found with emissions in excess of 4mW/cm

2

. The owner of the unit should be instructed not to use

the unit until the oven has been brought into compliance.

Summary of Contents for R-230HKL

Page 1: ...sult in a severe possibly fatal electrical shock High Voltage Capacitor High Voltage Power Transformer Magnetron High Voltage Rectifier Assembly High Voltage Harness etc R 230HK MODEL TABLE OF CONTENTS Page PRECAUTIONS TO BE OBSERVED BEFORE AND DURING SERVICING TO AVOID POSSIBLE EXPOSURE TO EXCESSIVE MICROWAVE ENERGY INSIDE FRONT COVER BEFORE SERVICING INSIDE FRONT COVER FOREWORD AND WARNING 1 PAR...

Page 2: ...transmission systems shall be repaired replaced or adjusted by procedures described in this manual before the oven is released to the owner e A microwave leakage check to verify compliance with the Federal Performance Standard should be performed on each oven prior to release to the owner BEFORE SERVICING Before servicing an operative unit perform a microwave emission check as per the Microwave Me...

Page 3: ...til the following points are ensured A The door is tightly closed B The door brackets and hinges are not defective C The door packing is not damaged D The door is not deformed or warped E There is no other visible damage with the oven Servicing and repair work must be carried out only by trained service personnel DANGER Certain initial parts are intentionally not grounded and present a risk of ele...

Page 4: ...ower transformer 1 BG 1 11 RTRN A661WRZZ Power transformer Interchangeable 1 BF 1 11 RTRN A659WRZZ Power transformer Interchangeable for production use 1 CABINET PARTS 2 1 GCABUA828WRPZ Outer case cabinet 1 BD 2 2 GLEGPA074WRE0 Foot 2 AC 2 3 PCUSUA605WRPZ Cushion 1 AG CONTROL PANEL PARTS 3 1 FPNLCB753WRKZ Control panel frame with key unit 1 BA 3 1 1 PSHEPA941WREZ Graphic sheet 1 AX 3 1 2 QSW KA029...

Page 5: ...mm 2 AA 7 10 XOTSD40P08000 Screw 4mm x 8mm 9 AA 7 11 XCPSD40P06000 Screw 4mm x 6mm 1 AA HOW TO ORDER REPLACEMENT PARTS To have your order filled promptly and correctly please furnish the following information 1 MODEL NUMBER 2 REF NO 3 PART NO 4 DESCRIPTION Order Parts from the authorized SHARP parts Distributor for your area Defective parts requiring return should be returned as indicated in the S...

Page 6: ...H OVEN AND CABINET PARTS 7 10 2 1 7 10 7 10 7 3 7 3 1 8 6 4 6 3 7 8 1 3 4 3 7 6 7 5 2 2 4 7 4 10 4 2 7 10 4 11 7 11 6 1 6 2 7 2 7 10 7 10 7 9 7 9 1 6 1 11 7 1 4 5 1 2 7 10 4 12 7 2 7 1 1 5 1 1 1 2 1 1 1 9 1 4 4 1 7 2 2 2 4 6 1 7 1 10 4 9 2 3 4 8 4 4 7 7 7 4 7 10 4 9 ...

Page 7: ... PANEL PARTS DOOR PARTS MISCELLANEOUS 5 2 6 6 5 5 5 3 5 4 5 6 5 7 5 1 5 8 Actual wire harness may be different than illustration 3 2 3 1 1 3 1 3 6 3 7 3 5 3 4 3 3 3 1 2 Before attaching Control unit to Control panel foil side of Control unit must be cleaned by ethyl alcohol ...

Page 8: ...BY SHARP CORPORATION ALL RIGHTS RESERVED No part of this publication may be reproduced stored in retrieval systems or transmitted in any form or by any means electronic mechanical photocopying recording or otherwise without prior written permission of the publisher ...

Reviews: