31
R-22GV
R-22GT
R-23GT
R-24GT
pictorial diagram. Be careful to ensure proper connection
of the wire leads.
4. Make sure that the monitor switches (1), (2) and all other
switches are operating properly. And check continuity of
the monitor circuit. Refer to chapter "Test Procedure"
and Adjustment procedure.
If the door sensing switch, secondary interlock switches (1),
(2) and monitor switches (1), (2) do not operate properly due
to a misadjustment, the following adjustment should be
made.
1. Loosen the two (2) screws holding latch hook to the oven
cavity front flange.
2. With door closed, adjust latch hook by moving it back and
forth, and up and down. In and out play of the door
allowed by the upper and lower position of the latch hook
should be less than 0.5mm. The vertical position of the
latch hook should be adjusted so that the door sensing
switch and secondary interlock switches (1), (2) are
activated with the door closed. The horizontal position of
the latch hook should be adjusted so that the monitor
switches (1), (2) are activated with the door closed.
3. Secure the screws with washers firmly.
4. Check the operation of all switches. If all switches have
not activated with the door closed, loosen two (2) screws
and adjust the latch hook position.
After adjustment, check the following.
1. In and out play of door remains less than 0.5mm when in
the latched position.
2. The door sensing switch and secondary interlock switches
(1), (2) interrupt the circuit before the door can be
opened.
DOOR SENSING SWITCH/SECONDARY INTERLOCK SWITCHES (1), (2)
AND MONITOR SWITCHES (1), (2) ADJUSTMENT
3. Monitor switches (1), (2) contacts close when door is
opened.
4. Re-install outer case and check for microwave leakage
around door with an approved microwave survey meter.
(Refer to Microwave Measurement Procedure.)
Latch head
Monitor switch (1)
Latch hook
Secondary interlock
switch (1)
Door sensing switch
Latch head
Joint lever
Door release
lever
Latch lever
Secondary interlock
switch (2)
Monitor switch (2)
Switch lever C
Switch lever A
Switch lever B
Figure C-2. Latch Switch Adjustments
(B) An approved microwave survey meter should be
used to assure compliance with proper microwave
radiation emission limitation standards.
DOOR ADJUSTMENT
Door adjustment is performed with the door properly in-
stalled and closed and while the oven hinges are loose.
1. Loosen upper and lower oven hinges with phillips head
screw driver.
2. Adjust the door by moving it vertically so that the top right
hand corner of the door is in line with the top of the control
panel frame assembly.
3. Tighten the upper and lower oven hinge screws.
After adjustment, make sure of the following:
1. Door latch heads smoothly catch the latch hook through
the latch holes, and the latch head goes through the
center of the latch hole.
2. Deviation of the door alignment from horizontal line of
cavity face plate is to be less than 1.0mm.
3. The door is positioned with its face depressed toward the
cavity face plate.
4. Re-install outer case and check for microwave leakage
around door with an approved microwave survey meter.
(Refer to Microwave Measurement Procedure.)
Note:
The door on a microwave oven is designed to act as
an electronic seal preventing the leakage of
microwave energy from oven cavity during cook
cycle. This function does not require that door be air-
REMOVAL
1. Disconnect oven from power supply
2. Remove outer case referring to "OUTER CASE, REAR
CABINET AND POWER SUPPLY CORD REMOVAL".
3. Remove the two (2) screws holding each of the upper
and lower oven hinges to the oven cavity.
4. Remove door assembly with upper and lower oven
hinges by pulling it forward.
5. Release upper and lower oven hinges from door
assembly.
6. Now, door assembly is free.
NOTE: When individual parts are replaced, refer to "Door
Disassembly".
RE-INSTALL
1. Insert the upper and lower oven hinges into door hinge
pins.
2. Insert the upper and lower oven hinges with door assembly
into rectangular holes of oven cavity front plate.
3. Make sure that the door is parallel with oven face lines
(left and upper side line) and door latch heads pass
through the latch holes correctly.
4. Fasten upper and lower oven hinges firmly to oven cavity
with two (2) screws on each hinge.
Note: After any service to the door;
(A) Make sure that door sensing switch, secondary
interlock switches (1), (2) and monitor switches (1),
(2) are operating properly. (Refer to chapter "Test
Procedures".).
DOOR REPLACEMENT