28
R-25AM
CONTROL PANEL ASSEMBLY REMOVAL
The complete control panel should be removed for re-
placement of components. To remove the control panel,
proceed as follows:
1. Disconnect the oven from power supply.
2. Wait for 60 seconds to discharge the high voltage
capacitor.
3. Remove the air intake filter assembly from the base
plate.
4. Remove two (2) screws holding the control panel to the
base plate.
5. Pull down the control panel and remove it forward.
6. Disconnect connectors and wire leads from the control
unit.
7. Now the control panel assembly is free.
CAUTION FOR TOUCH CONTROL PANEL REMOVAL
1) Hold the lower end (Position A, Fig. 1) of the touch
control panel assembly firmly while sliding it down and
toward you.
2) If the Touch Control Panel is hard to remove;
(1) Insert a flat head screw driver into space B . (Fig. 1)
(2) Rotate the screwdriver clockwise while holding posi-
tion C of the Touch Control Panel. (Fig. 2)
TO AVOID DAMAGE TO TOUCH CONTROL PANEL,
COVER THE TIP OF SCREWDRIVER WITH TAPE.
Installation
1. Insert the receptacle into terminal insulator.
2. Close covers of the terminal insulator, as shown
illustlated below.
CONTROL PANEL ASSEMBLY AND CONTROL UNIT REMOVAL
Replacement of individual component is as follows:
CONTROL UNIT AND CONTROL PANEL FRAME
(WITH SWITCH UNIT)
8. Remove three (3) screws holding the control panel
mounting angle to the panel frame.
9. Lift up the control panel mounting angle from the
panel frame.
10.Disconnect the connectors (G) and (E) from the
control unit.
11.Remove four (4) screws holding the control unit to
the panel frame assembly.
12.Now, the control unit and control panel frame (with
switch unit) are free.
CAUTION:
At installing control panel unit assembly to main
body set:
1. Ensure the installation of wiring-related parts
without negligence.
2. When inserting wire cable to main body set,
ensure them free from caught-in trouble. In
addition, when installing the control panel
assembly to base plate with screws, be sure of
pushing the control panel unit upward to fix with
screws firmly.
3. Do not allow any wire leads to come near the
varistor works, because it will explode and the
wire leads near by the varistor will be damaged.
SWITCH UNIT
13.Remove the three (3) screws holding the switch unit
(Main) to the control panel frame.
14.Remove the two (2) screws holding the switch unit
(Sub.) to the control panel frame.
15.Now, the switch unit is free
ROTARY ENCODER UNIT
13.Remove the two (2) screws holding the rotary
encoder unit to the control panel frame.
14.Remove the knob from the rotary encoder shaft.
15.Remove the one (1) special nut holding the rotary
encoder to the rotary encoder mounting plate.
16.Now, the rotary encoder is free.
POWER SUPPLY CORD REPLACEMENT
Flat type
screw driver
Terminal
insulator
RECEPTACLE
COVERS
B
A
C
B
Fig. 1
Fig. 2
TOUCH CONTROL PANEL
SCREW DRIVER
1. CARRY OUT 3D CHECKS
2. Release the cord bushing from the rear cabinet.
3. Disconnect the brown and blue wires of the power
supply cord from the noise filter.
4. Remove the single (1) screw holding the earth wire of
power supply cord.
5. Remove the power supply cord.