GB-19
Make sure the terminal screws are tight and the cable
is held securely by the cable grip where it enters the
plug.
Like most appliances in your home, your oven must
be connected to a single phase 230-240V, 50Hz
alternating current supply.
If you do not make the proper electrical connections
you might damage the oven or injure yourself.
Neither SHARP nor the supplier will be liable if this
happens.
WARNING: THIS APPLIANCE MUST BE EARTHED
If you have any doubts about your electrical
supply ask a qualifi ed electrician.
DEFROSTING ADVICE
TO REPLACE THE MAINS PLUG
The wires in the mains cable are colour coded as
shown:
Green and yellow stripes =
EARTH
Blue
=
NEUTRAL
Brown
=
LIVE
As the colours in the mains lead of your oven may not
correspond with the coloured marking identifying
the terminals in your plug, connect the wires as
described:
• The green and yellow wire to the plug terminal
marked E
or
or
coloured green
or
coloured
green and yellow.
• The blue wire to the plug terminal marked N
or
coloured black
or
coloured blue.
• The brown wire to the plug terminal marked L
or
coloured red
or
coloured brown.