R21LTF
11 – 3
[7] OVEN LAMP AND LAMP SOCKET REMOVAL
1. Disconnect the power supply cord, and remove outer case.
2. Open the door and block it open.
3. Discharge high voltage capacitor.
4. Lift up the oven lamp socket from air intake duct.
5. Pull the wire leads from the oven lamp socket by pushing the termi-
nal hole of the oven lamp socket with the small flat type screw
driver.
6. Now, the oven lamp socket is free.
Figure C-1. Oven lamp socket
[8] POSITIVE LOCK CONNECTOR (NO-CASE TYPE) REMOVAL
1. Disconnect the power supply cord, and remove outer case.
2. Open the door and block it open.
3. Discharge high voltage capacitor.
4. Push the lever of positive lock
®
connector.
5. Pull down on the positive lock
®
connector.
CAUTION: WHEN CONNECTING THE POSITIVE LOCK
®
CONNEC-
TORS TO THE TERMINALS, NSTALL THE POSITIVE
LOCK
®
SO THAT THE LEVER FACES YOU.
Figure C-1. Positive Lock
®
Connector
[9] ANTENNA MOTOR REMOVAL
1. Disconnect the power supply cord.
2. Remove the one (1) screw holding the base plate cover to the base
plate and remove the base plate cover.
3. Disconnect the wire leads from the antenna motor and remove the
one (1) screw holding the antenna motor.
4. Remove the antenna motor shaft from the antenna motor.
5. Now, the antenna motor is free.
[10] COOLING FAN MOTOR REMOVAL
1. REMOVAL
1. Disconnect the power supply cord and remove outer case.
2. Open the door and block it open.
3. Discharge high voltage capacitor.
4. Disconnect the wire leads from the fan motor.
5. Remove the one (1) screw holding the capacitor holder to the oven
cavity rear plate.
6. Remove the one (1) screw holding the fan duct to the oven cavity
rear plate.
7. Release the tabs of the capacitor holder from fan duct.
8. Remove the fan duct from the oven.
9. Remove the fan blade from the fan motor shaft according to the fol-
lowing procedure.
10.Hold the edge of the rotor of the fan motor by using a pair of groove
joint pliers.
CAUTION: MAKE SURE THAT ANY PIECES DO NOT ENTER THE
GAP BETWEEN THE ROTOR AND THE STATOR OF THE
FAN MOTOR. BECAUSE THE ROTOR IS EASY TO BE
SHAVEN BY PLIERS AND METAL PIECES MAY BE PRO-
DUCED.
DO NOT TOUCH THE PLIERS TO THE COIL OF THE
FAN MOTOR BECAUSE THE COIL MAY BE CUT OR
INJURED.
DO NOT DISFIGURE THE BRACKET BY TOUCHING
WITH THE PLIERS.
11.Remove the fan blade assembly from the shaft of the fan motor by
pulling and rotating the fan blade with your hand.
12.Now, the fan blade will be free.
CAUTION: DO NOT RE-USE THE REMOVED FAN BLADE
BECAUSE THE HOLE (FOR SHAFT) MAY BE LARGER
THAN NORMAL.
13.Remove the two (2) screws holding the fan motor to the fan duct.
14.Now, the fan motor is free.
Oven lamp socket
Terminal
Wire lead
Terminal hole
Flat type small screw driver
Terminal
Push
Pull down
1
2
Lever
Positive lock
connector
R