QT-CD700W
28
Yes
Yes
No
No
No
Yes
Yes
No
Yes
No
SDOUT
FF
REW
SL
FF
REW
SD OUT
Is following slide feed signal output the pin 23 (SDOUT) of
IC101A when UP/DOWN key is pressed after the CD TEST
MODE is set?
Is following slide feed signal input the pins 12 and 13 IC601
when UP/DOWN key is pressed after the CD TEST MODE
is set?
Is slide feed signal output the pins 1 and 2 of IC601?
Is slide feed voltage applied between both terminals of
slide motor?
Check the CD mechanism (periphery of slide motor). If the
slide motor does not run when DC2.0V is applied to both
terminals of slide motor, the slide motor is faulty.
Is following slide signal output the pin 23 (SD OUT) of
IC101A during playback?
* Slide motor operation failure.
* Slide servo failure.
Normal.
IC101A is faulty.
IC101A is faulty.
Check the PWB pattern between pin 23 of IC101A and pins
12 and 13 of IC601.
Check the CN2.
Check the peripheral parts of IC601. If OK, IC601 is faulty.