47
E
RS-232C command table
How to read the command table
Command:
Command field (See page 45.)
Direction:
W When the “Parameter” is set in the parameter field (see page 45), the command functions as described
under “Control/Response Contents”.
R The returned value indicated under “Reply” can be obtained by setting “????”, “
?” or “???+”
(repeater control) in the parameter field. (See page 45.)
Parameter:
Parameter field (See page 45.)
Reply:
Response (Returned value)
* :
When POWER SAVE MODE is set to OFF:
“●/○” : Indicates a command which can be used in standby mode or when the power is on.
“–” : Indicates a command which can be used when the power is on. Cannot be used in standby mode.
When POWER SAVE MODE is set to ON:
“●” : Indicates a command which can be used in standby mode or when the power is on.
“○/–” : Indicates a command which can be used when the power is on. Cannot be used in standby mode.
Power control/Input mode selection
Function
Command Direction
Parameter
Reply
Control/Response contents
*
Power control
POWR
W
0
Switches to standby mode.
●
1
Returns from standby mode.
R
0 Standby mode
1 Normal mode
2 Input signal waiting mode
Input mode selection
INPS
W
0
Toggle change for input mode.
2
D-SUB
10
HDMI1
13
HDMI2
14
DisplayPort
21
OPTION
“ERR” when nothing is attached in the expansion slot.
24
APPLICATION
R
2 D-SUB
10 HDMI1
13 HDMI2
14 DisplayPort
21 OPTION
24 APPLICATION
SCREEN menu
Function
Command Direction
Parameter
Reply
Control/Response contents
*
AUTO
ASNC
W
1
When the input mode is D-SUB.
-
CLOCK
CLCK
WR
0-1200
0-1200 When the input mode is D-SUB.
Varies depending on the signal.
PHASE
PHSE
WR
0-63
0-63 When the input mode is D-SUB.
POSITIONING
POSITION OF THE LONGEST
DIRECTION
HPOS
WR
0-800
0-800 When the input mode is D-SUB.
Varies depending on the signal.
POSITION OF THE SHORTEST
DIRECTION
VPOS
WR
0-200
0-200 When the input mode is D-SUB.
Varies depending on the signal.
RESOLUTION
SETTING
LONGEST DIRECTION
RESOLUTION
HRES
WR
300-1920
300-1920 When the input mode is D-SUB.
Only even numbers are valid for parameters.
Varies depending on the signal.
SHORTEST DIRECTION
RESOLUTION
VRES
WR
300-1200
300-1200
INPUT SIGNAL (D-SUB)
PXSL
WR
1
1 768) 1360 x 768
2
2 768) 1280 x 768
3
3 768) 1024 x 768
5
5 480) 848 x 480
6
6 480) 640 x 480
7
7 1050) 1680 x 1050
8
8 1050) 1400 x 1050
9
9 768) AUTO
10
10 480) AUTO
Check the resolution
PXCK
R
- Returns current resolution in the form of hhh, vvv.
RESET
ARST
W
1
Controlling the Monitor with a computer (RS-232C)