Thank you for purchasing this SHARP Plasmacluster Ion Generator. Please 

read this manual carefully before using Plasmacluster Ion Generator.

After reading, keep the manual in a convenient location for future reference.

The information provided in this manual is subject to change without no-

tice.

CONTENTS

IMPORTANT SAFETY INSTRUCTIONS

 ......................E-2

• WARNING ............................................................................E-2

• CAUTIONS CONCERNING OPERATION ...........................E-2

• INSTALLATION GUIDELINES .............................................E-2

PARTS NAME

 .....................................................................E-3

• FRONT .................................................................................E-3

• BACK ...................................................................................E-3

INSTALLATION POSITION

 .............................................E-4

OPERATION

 .......................................................................E-4

CLEANING AND MAINTENANCE

 .................................E-5

• MAIN UNIT ...........................................................................E-5
• FILTER .................................................................................E-5

PLASMACLUSTER ION GENERATING UNIT REPLACEMENT

 ...E-6

HOW TO REPLACE THE PLASMACLUSTER ION GENERATING UNIT

 ...E-7

SPECIFICATIONS

 .............................................................E-8

TROUBLESHOOTING

 ......................................................E-8

•  While  IG-BL20E  can  inactivate  suspended  viruses  and  other  con-

taminants, it cannot create a completely sterile environment. SHARP 

does not guarantee its ability to prevent microbial infection.

•  To  enable  stable  emission  of  high-density  Plasmacluster  ions,  the 

Plasmacluster Ion Generating Unit mounted in IG-BL20E will need to 

be replaced periodically*.

*Replacement  is  required  approximately  every  2  years  (17,500  hours)  when  oper

-

ated 24 hours a day. 

IG-BL20E

 will stop operating after about 26 months (9,000 

hours) if the Plasmacluster Ion Generating Unit is not replaced.

BL20E.indd   1

09.12.4   2:37:34 PM

Summary of Contents for Plasmacluster IG-BL20E

Page 1: ...d keep this manual carefully ENGLISH The number in this technology mark indicates an approximate number of ions supplied into air of cm3 which is measured around the center of a room with the applicable floor area at 1 2 m height above the floor at the maximum wind volume when plasmacluster ion evolving equipment using the high density plasmacluster ion evolving unit is placed close to a wall ...

Page 2: ......

Page 3: ... 5 MAIN UNIT E 5 FILTER E 5 PLASMACLUSTER ION GENERATING UNIT REPLACEMENT E 6 HOW TO REPLACE THE PLASMACLUSTER ION GENERATING UNIT E 7 SPECIFICATIONS E 8 TROUBLESHOOTING E 8 While IG BL20E can inactivate suspended viruses and other con taminants it cannot create a completely sterile environment SHARP does not guarantee its ability to prevent microbial infection To enable stable emission of high de...

Page 4: ...physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or in struction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the appliance CAUTIONS CONCERNING OPERATION Do not ride the main unit and do not sit on or lean it it may cause injury or malfun...

Page 5: ...on 3sec Unit Replacing Light Filter Clean Light Operation Button Fan Speed Indicator LOW MED HIGH Front Louver Air Outlet Front Caution Label Back Louver Air Outlet Back Cluster Door Power Cord Plug Shape of plug depends on country Handle Plasmacluster Ion Generating Unit Filter Air Intake ...

Page 6: ...s polish glass cleaner wipe and wax SIDE More than 60cm BACKSIDE More than 10cm SIDE More than 60cm OPERATION Press the operation button to directly turn on the power and select the preferred mode Operation Button Lights Control Button LOW MED OFF Release high density Plasmacluster ions quietly Release high density Plasmacluster ions at medium fan speed Release high density Plasmacluster ions at h...

Page 7: ...en if necessary Filter FILTER CLEAN LIGHT FILTER CLEAN LIGHT lights up after approx 1 month approx 720 hours when operated 24 hours a day Press FILTER RESET Button it sounds and the light is turned off Lighting orange Detach the filter and remove dust with using a vacuum cleaner Detach Clean Attach Tab Push the both tabs toward arrow Set one side of the filter tab first Push and set the another si...

Page 8: ...sary The Unit Replacing Light lights up as a reminder for replacement Plasmacluster Ion Generating Unit for Replacement Usage environment affects the lifetime of the Plasmacluster Ion Generator The Plasmacluster Ion Generator may stop operating before estimated lifetime In this case press Operation button again and restart If this does not help replace with a new Plasmacluster Ion Generating Unit ...

Page 9: ...one like the coin and open the Cluster Door Remove the Plasmacluster Ion Generating Unit by the handle Replace the new Plasmacluster Ion Generating Unit Fix it into the main unit firmly Never touch the connector terminal of Plasmacluster Ion Generating Unit After replacing the Plasmacluster Ion Generating Unit press the Operation Button Fill the replacement date on the label of side of the main un...

Page 10: ...when the main unit is placed near a wall 2 Ion count per cm3 blown into air at around the center of the room at a height of approx 1 2m from the floor during operation at each airstream setting when the main unit is placed near the wall The number of ions will vary according to the room conditions and operation mode TROUBLESHOOTING Before calling for service please review the TROUBLESHOOTING chart...

Page 11: ...ENGLISH ENGLISH E ...

Page 12: ...SHARP CORPORATION Osaka Japan Printed in China TINS A399KKRZ 09M CN 1 ...

Reviews: