AYZP40KR
1 – 1
AYZP40KR
Service Manual
CHAPTER 1.
PRODUCT SPECIFICATION
[1] SPECIFICATION
1. AYZP40KR – AEZ40KR
NOTE: The conditions of star”
☆
” marked item are based on “EN14511”.
MODEL
INDOOR UNIT
OUTDOOR UNIT
ITEMS
AYZP40KR
AEZ40KR
Rated cooling capacity (Min– Max.)
kW
3.5 (0.9 - 4.0)
Rated heating capacity (Min–Max.)
kW
4.0 (0.9 - 6.0)
Moisture removal (at cooling)
Liters/h
1.2
Electrical data
Phase
Single
Rated frequency
Hz
50
Rated voltage
V
220-240
Rated current
☆
(Min - Max.)
Cool
A
4.7 (0.9 - 5.7 )
Heat
A
4.4( 0.9 - 7.4 )
Rated input
☆
(Min - Max.)
Cool
W
1000 (200- 1250)
Heat
W
950 (200 - 1700)
Power factor
☆
Cool
%
93
Heat
%
94
Compressor
Type
Hermetically sealed rotary type
Model
DA111A1F22F
Oil charge
450cc (Ester oil VG74)
Refrigerant system
Evaporator
Louver Fin and Grooved tube type
Condenser
Corrugate Fin and Grooved tube type
Control
Expansion valve
Refrigerant (R410A)
990g
De-lce system
Micro computer controled reversed systems
Noise level
(at cooling)
High
dB(A)
40
47
Low
dB(A)
–
–
Soft
dB(A)
28
–
Fan system
Drive
Direct drive
Air flow quantity
(at cooling)
High
m3/min.
10.6
30.2
Low
m3/min.
8.7
–
Soft
m3/min.
6.9
–
Fan
Cross flow fan
Propeller fan
Connections
Refrigerant coupling
Flare type
Refrigerant tube size Gas, Liquid
3/8", 1/4"
Drain piping mm
O.D
16
Others
Safety device
Compressor: Thermal protector
Fan motors: Thermal fuse
Fuse, Micro computer control
Air filters
Polypropylene net (Washable)
Net dimensions
Width
mm
860
780
Height
mm
292
540
Depth
mm
205
265
Net/Gross weight
kg
9/12