WARNING:

High brightness light source, do not stare into the beam of light, or view directly. Be especially
careful that children do not stare directly into the beam of light.

WARNING:

TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS UNIT TO
MOISTURE OR WET LOCATIONS.

CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK,

DO NOT REMOVE CABINET.

NO USER-SERVICEABLE PARTS EXCEPT LAMP UNIT.

REFER SERVICING TO QUALIFIED SERVICE

PERSONNEL.

The lighting flash with arrowhead within a
triangle is intended to tell the user that
parts inside the product are risk of electric
shock to persons.

The exclamation point within a triangle is
intended to tell the user that important
operating and servicing instructions are in
the manual with the projector.

CAUTION

AVERTISSEMENT: Source lumineuse de grande intensité. Ne pas fixer le faisceau lumineux ou le regarder

directement. Veiller particulièrement à éviter que les enfants ne fixent directement le
faisceau lumineux.

AVERTISSEMENT: AFIN D’EVITER TOUT RISQUE D’INCENDIE OU D’ELECTROCUTION, NE PAS PLACER

CET APPAREIL DANS UN ENDROIT HUMIDE OU MOUILLE.

L’éclair terminé d’une flèche à l’intérieur
d’un triangle indique à l’utilisateur que les
pi‘eces se trouvant dans l’appareil sont
susceptibles de provoquer une décharge
électrique.

Le point d’exclamation à l’intérieur d’un
triangle indique à l’utilisateur que les
instructions de fonctionnement et
d’entretien sont détaillées dans les
documents fournis avec le projecteur.

RISQUE

D’ÉLECTROCUTION. NE
PASR ETIRER LES VIS Á

L’EXCEPTION DE LA VIS DE

REPARATION UTILISATEUR

SPECIFIEES

ATTENTION

ATTENTION: POUR EVITER TOUT RISQUE

D’ELECTROCUTION, NE PAS RETIRER LE CAPOT.

AUCUNE DES PIECES INTERIEURES N’EST REPARABLE

PAR L’UTILISATEUR, A L’EXCEPTION DE L’UNITE DE

LAMPE. POUR TOUTE REPARATION, S’ADRESSER A UN

TECHNICIEN D’ENTRETIEN QUALIFIE.

RISK OF ELECTRIC SHOCK.
DO NOT REMOVE SCREWS

EXCEPT SPECIFIED USER

SERVICE SCREW.

CAUTION

(POWER Unit)

For continued
protection against a
risk of fire, replace
only with same type
6.3A, AC250V fuse.
(F701)

PRECAUTION

(Unité de PUTSSANCE)

Pour une protection
continue contre un
risques d’incendie, ne
remplacer qu’avec un
fusible 6.3A,AC250V

du même type.

(F701)

6.3A 250V

6.3A 250V

Summary of Contents for PG-F200X - Notevision XGA DLP Projector

Page 1: ...T SERVICE SAFETY NOTES ii Precautions for using lead free solder vii CHAPTER 1 OPERATION MANUAL 1 Specifications 1 1 CHAPTER 2 ELECTRICAL ADJUSTMENT 1 ELECTRICAL ADJUSTMENT 2 1 2 Adjustment mode process menu 2 4 Parts Guide TopPage CONTENTS In the interests of user safety Required by safety regulations in some countries the set should be restored to its orig inal condition and only parts identical...

Page 2: ... Some parts changed DMD Unit DUNTKE154WEF0 DUNTKE150WEF0 BALLAST CONTROL Unit P7701 Plug QPLGN0864TAZZY No Delete R7794 Resistor VRS CY1JF100JY No Delete R7795 Resistor VRS CY1JF100JY No Delete R7796 Resistor VRS CY1JF100JY No Delete DUNTKE153FMF8 MAIN Unit C3586 Capacitor VCKYCY1HB102KY VCKYCY1EB333KY Changed C3588 Capacitor VCKYCY1HB102KY VCKYCY1EB333KY Changed C3591 Capacitor VCKYCY1HB102KY VCK...

Page 3: ...ure the AC voltage drop across the resistor All checks must be repeated with the AC plug connection reversed If necessary a non polarized adapter plug must be used only for the purpose of completing these checks Any reading of 0 4 volts RMS this corresponds to 0 27 milliamp AC or more is excessive and indicates a potential shock hazard which must be corrected before returning the unit to the owner...

Page 4: ...s qui présentent une voie de retour au châssis antenne coffret métallique tête des vis arbres de commande et des boutons écusson etc et mesurer la chute de tension CA en travers de la résistance Toutes les vérifications doivent être refaites après avoir inversé la fiche du cordon d alimentation Si nécessaire une prise d adpatation non polarisée peut être utilisée dans le but de terminer ces vérifi...

Page 5: ...tion UV éviter tout contact direct avec les yeux 5 La lampe moyenne pression implique un risque d explosion Toujours suivre les instructions d installation décrites ci dessous et manipuler la lampe avec soin NOTE TO SERVICE PERSONNEL UV RADIATION PRECAUTION The light source lamp in the projector emits small amounts of UV Radiation AVOID DIRECT EYE AND SKIN EXPOSURE To ensure safety please adhere t...

Page 6: ...om an opening between the exhaust fans it is rec ommended to place the cap of the optional lens on the opening during servicing to avoid eye and skin exposure DANGER Never turn the power on without the lamp to avoid electric shock or damage of the devices since the stabilizer generates high voltages at its start UV RADIATION PRECAUTION Continued Lamp Replacement Note Since the lamp reaches a very ...

Page 7: ...UT RISQUE D INCENDIE OU D ELECTROCUTION NE PAS PLACER CET APPAREIL DANS UN ENDROIT HUMIDE OU MOUILLE L éclair terminé d une flèche à l intérieur d un triangle indique à l utilisateur que les pi eces se trouvant dans l appareil sont susceptibles de provoquer une décharge électrique Le point d exclamation à l intérieur d un triangle indique à l utilisateur que les instructions de fonctionnement et d...

Page 8: ...higher than the conventional lead solder by 40 C and as it has poor solder wettability you may be apt to keep the soldering bit in contact with the PWB for extended period of time However Since the land may be peeled off or the maximum heat resistance temperature of parts may be exceeded remove the bit from the PWB as soon as you confirm the steady soldering condition Lead free solder contains mor...

Page 9: ...Rated voltage Rated frequency Input current Power consumption Standby Operation temperature Cabinet Dimensions main body only Weight approx F number Zoom Focus DVI D Compatible with HDCP RGB Component mini D sub 15 pin S Video mini DIN 4 pin Video RCA Audio φ3 5 mm stereo minijack Audio RCA RGB Component mini D sub 15 pin Audio φ3 5 mm stereo minijack USB Type B RS 232C mini DIN 9 pin PG F200X 0 5...

Page 10: ... 2 On the screen where bit dropouts occur raise the values of R G B Contrast Adjust the values so that bright red green and blue bit dropouts appear on a black background and amounts of change in x value of R and y values of G B become 100 1000 or more 3 If adjustment is performed manually watching the screen make adjustment so that bright red green and blue bit dropouts appear on more than half o...

Page 11: ...50 gray signal 2 Select the following group and subjects Group CONFIRM VIDEO Subject V R OS V B OS 1 V R OS is 132 V B OS is 132 10 White balance checking and readjustment 1 RGB Input sRGB Input VIDEO Input DTV Input DVD Input 1 Check that there is no deviation of white balance with the monitor 11 Off timer performance 1 Select the following group and subjects Group CONFIRM CHECK Subject TEMP OFF ...

Page 12: ... be properly adjusted with other sig nals Resetting the lamp timer for this model 1 Resetting procedure In Stand by run this command to clear the operating time of the lamp to 0 and turn on the power Press and hold ENTER and MENU and then press the STANDBY ON key of the set Forced disabling of the System Lock of this model 1 Disabling procedure With System Lock input window onscreen press the MENU...

Page 13: ...56 B BLK 256 S R OS 128 S G OS 128 S B OS 128 VIDEO V CONT 124 V BRIGHT 68 V COLOR 154 V HUE 128 V R OS 132 V G OS 128 V B OS 132 OFFSET MODE 0 OFFSET CONT 0 OFFSET BRI 0 MODEL MODEL SELECT 0 CHECK LED CHK 0 TEMP OFF INFO VERSION MODEL VER PATTERN RGB 1 RGB50 1 CORSS 1 STEP 1 COLOR 1 CHR 1 LAMP CURRENT 0 HISTORY1 0 HISTORY2 0 HISTORY3 0 HISTORY4 0 TOTAL 0 TEMP FAN TEMP1 TEMP2 FAN0 3 FAN1 3 FAN2 3 ...

Page 14: ... R7805 of the ballast control PWB DUNTKE150WEF0 so that the voltage of the tester reaches 71 0 5V Adjustment value 71 0 5V CAUTION 1 Caution for electric shock Do not touch the test points TP1 and TP2 of the adjustment jig when supplying power since a high voltage and large current is applied to them 2 Caution for heat Be careful that the resistance load of the adjustment jig produces a high tempe...

Page 15: ... sales service only The contents are subject to change without notice PG F200X PartsGuide 1 PRINTED WIRING BOARD ASSEMBLIES 2 DUNTKE153FMF8 MAIN Unit 3 CABINET AND MECHANICAL PARTS 4 OPTICAL MECHANISM PARTS 5 SUPPLIED ACCESSORIES 6 PACKING PARTS NOT REPLACEMENT ITEM 7 SERVICE JIGS AND EQUIPMENT USE FOR SERVICING CONTENTS No S77O5PG F200X PG F200X MODEL DATA PROJECTOR Note The reference numbers on ...

Page 16: ...FMG0 when replacing ballast power unit DUNTKE149WEF0 N DUNTKE150WEF0 BW N J BALLAST CONTROL Unit N DUNTKE151WEF0 AY N J PHOTO SENSOR Unit N DUNTKE152WEF0 AY N J R C RECEIVER Unit N DUNTKE153FMF8 CT N J MAIN Unit N DUNTKE154WEF0 CN N J DMD Unit without the DMD chip 2 DUNTKE153FMF8 MAIN Unit C3586 VCKYCY1EB333KY AA J Capacitor 0 033 25V Ceramic C3588 VCKYCY1EB333KY AA J Capacitor 0 033 25V Ceramic C...

Page 17: ... MECHANICAL PARTS 18 42 1 2 1 5 1 1 1 3 1 4 1 10 19 40 25 30 40 29 24 6 12 15 2 1 2 1 3 2 1 1 2 1 2 40 41 37 26 2 8 2 2 4 2 6 2 9 2 7 9 40 2 3 2 5 27 16 14 2 2 10 40 34 39 33 39 38 8 4 5 10 17 23 43 45 22 32 2 10 2 11 44 10 31 ...

Page 18: ... XR30LP N Lamp Unit 6 LHLDFA011WJKZ AC J Rivet Power PWB 8 LHLDZA849WJKZ AQ N J Holder Bimetal 9 LX BZ3049GEFN AB J Screw x4 10 LX BZ3100CEF7 AA J Screw x7 12 LX BZA186WJF9 AD N J Screw x2 14 NFANRA076WJ00 BM N J Fan 15 NFANRA078WJ00 BP N J Fan 16 PCOVPA037WJSB AM N J Cover 17 PCOVUA105WJ00 AF N J Cover 18 PCOVZA099WJZZ AE N J Cover 19 PCOVZA100WJZZ AF N J Cover 22 PSLDMB118WJFW AM N J Shield 23 P...

Page 19: ... 32 4 32 4 33 4 16 4 11 4 33 4 27 4 29 4 33 4 33 4 30 4 24 4 36 4 12 4 18 4 33 4 33 4 33 4 33 4 31 4 31 4 31 4 33 4 33 4 26 4 31 4 31 4 23 4 14 4 31 4 31 4 31 4 28 4 15 4 20 4 33 4 33 4 21 4 22 4 33 4 33 4 34 4 34 4 33 4 13 4 25 4 1 4 4 4 9 4 8 4 7 4 5 4 6 4 2 4 3 11 11 13 13 20 7 35 36 28 21 11 11 13 13 ...

Page 20: ...059WJZZ BF J Lens 4 19 PLNS A080WJZZ AT N J Lens 4 20 PLNS A083WJZZ AT N J Lens 4 21 PLNS A084WJZZ AT N J Lens 4 22 PLNS A085WJZZ BD N J Lens 4 23 PMiR A125WJZZ AU N J Mirror 4 24 PRDARA446WJFW AQ N J Heat Sink 4 25 PSLDHA048WJFW AK N J Shield 4 26 PSLDPA077WJFW AM N J Shield 4 27 PSLDPA072WJKZ AZ N J Shield 4 28 PSLDPA073WJFW AD N J Shield 4 29 RH HXA040WJQZ AS N J Thermistor 4 30 TLABZB026WJZZ A...

Page 21: ...5WJPZ AU J RGB Cable X4 RRMCGA581WJSA BD N J Remote Control X5 TCAUZA187WJZZ AC J WEEE Caution Sheet Except U S A and Canada X6 TGAN A232WJZZ AC J SEC ER Information PG F200XU X7 TGAN A233WJZZ AC J SECL ER Information PG F200XU X8 TLABZA255WJZZ AE J ER Sticker PG F200XU X9 TGAN A811WJZZ AB J SECL Warranty for Canada X10 TGAN A848WJZZ AK N J SEC Warranty PG F200XU X11 TiNS D372WJZZ AQ N J Operation...

Page 22: ...PG F200X 8 6 PACKING PARTS NOT REPLACEMENT ITEM S1 S3 S7 S6 S4 S5 S8 S9 S9 S2 ...

Page 23: ... S8 TLABVA333WJZZ Bar Code Label for U S A Canada Australia New Zealand and Oceania S9 TLABZA957WJZZ C W Mark Label x2 for Europe and Singapore 7 SERVICE JIGS AND EQUIPMENT USE FOR SERVICING N QCNW C516WJQZ AG J Extension Cable 3pins L 200mm Main to Fan x2 N QCNWKA006WJZZ AX J Extension Cable 4pins L 500mm Main to Fan N QCNWKA008WJZZ AP J Extension Cable 14pins Main to Power N QCNWKA019WJZZ BU J E...

Page 24: ... form or by any means electronic mechanical photocopying recording or otherwise without prior written permission of the publisher COPYRIGHT XXXX BYSHARP CORPORATION ALL RIGHTS RESERVED 2007 TQ2279 S YK DS SHARP CORPORATION AV Systems Group CS Promotion Center Yaita Tochigi 329 2193 Japan PG F200X ...