SHARP PC-G850V(S) User Manual -
Appendix A: 11-Pin Interface
9
SIO-Mode: RS-232 Printer
With the SIO-mode you can also make use of printers that provide an RS-232 interface,
like the 4-color plotter CE-515P or CE-516P.
Do not connect an RS-232-printer to the PC-G850V(S) without a voltage level converter!
The data transfer cable/converter CE-T800/801 can be used in combination with a null-
modem wiring or adaptor. To connect the CE-515P/516P via RS-232 a DIN-4 plug is
needed. The correct wiring (inluding null-modem) is as follows:
Be sure to have the DIP-switches on the back side of the CE-515P/516P configured
correctly (see printer manual for details).
Furthermore you have to adopt the RS-232 parameters in the TEXT/Sio/Format sub-
menue of the PC-G850V(S) in order to get a connection with the CE-515P:
•
baud rate = 1200
•
data bit
= 8
•
stop bit
= 1
•
parity
= none
•
end of line = CR
•
flow
= RS/CS
Now, to actually direct outputs to a RS-232-printer, you have to open the 11-pin interface
explicitely in SIO-mode (
OPEN“COM:“
) – and close it after use (
CLOSE
). Character-
strings and control codes are transmitted via the
PRINT#1,“...”
command in
between.
OPEN“COM:“
PRINT#1,“HELLO WORLD“
…
CLOSE
The commands
LPRINT
,
LLIST
,
LFILES
however are not routed to the 11-pin interface
in SIO-mode.
DIN-4 Plug
CE-T800/1 DB-25 Plug
Pin# Signal
Pin# Signal
1
+12V
-
-
2
BUSY#
4
RTS
3
GND
7
GND
4
DATA#
3
RXD