background image

SIM02E-010C+E 

 

2

whether the PV modules are connected or not. 

4. 

PV modules produce electricity when the sufficient sunlight 
or other sources illuminate the PV module surface. When 
the  PV  modules  are  connected  in  series,  voltage  is 
cumulative.  When  the  PV  modules  are  connected  in 
parallel, current is cumulative. As a result, a large-scale PV 
system can produce high voltage and current which could 
present an increased hazard and may cause serious injury 
or death. 

5. 

Do not connect the PV modules directly to the loads such 
as motor since the variation of the output power depending 
on the solar irradiation causes damage for the connected 
motor. 
1:  In  the  case  of  a  brushless  motor,  the  lock  function 

becomes  active  and  the  hall  IC  is  most  likely  to  be 
damaged. 

2: In the case of a brush type motor, the coil is most likely 

to be damaged. 

6. 

In case of snow build-up, snow would slide easier on the 
smooth surface of the PV module than other parts of the 
roof.  Snow  may  suddenly  slide,  fall  off  the  roof  and  hit 
nearby  objects/areas.  Take  preventive  measures  (e.g. 
snow stopper) when there is possible risk such case would 
cause an injury or a damage. 

 

GENERAL SAFETY 

1. 

Consult local codes and other applicable laws concerning 
required  permits  on  regulations  for  installation  and 
inspection requirements. 

2. 

Before  installing  a  PV  module,  contact  appropriate 
authorities to determine permit, installation and inspection 
requirements that should be followed. 

3. 

Install PV modules and ground frames in accordance with 
applicable rules and regulations. 

4. 

PV  modules  should  be  installed  and  maintained  by 
qualified  personnel.  Only  installer/servicer  personnel 
should have access to the PV module installation site. 

5. 

No matter where the PV modules are installed, either roof 
mounted construction or any other type of structures above 
the  ground,  appropriate  safety  practices  should  be 
followed and required safety equipment should be used in 
order  to  avoid  possible  safety  hazards.  Note  that  the 
installation of some PV modules on roofs may require the 
addition  of  fireproofing,  depending  on  local  building/fire 
codes. 

6. 

In the case that the PV modules are non-integral type, the 
PV module is to be mounted over a fire resistant roof. 

7. 

Use PV modules with the same cell size within series. 

8. 

Follow all safety precautions of other components that are 
used in the system. 

9. 

In order to avoid a risk of injury or electrical shock, do not 
allow anyone to approach the PV module if the person has 
little  knowledge  on  PV  module  or  on  the  measures  that 
should be taken when PV modules are damaged. 

10.  Do not shade portions of the PV module surface from the 

sunlight for a long time. The shaded cell may become hot 
(hot  spot  phenomenon)  which  results  in  solder  joints 
peeling  off.  Shading  causes  drop  in  generated  power 
and/or operation failure of the PV modules. 

11.  Do not clean the glass surface with chemicals. Do not let 

water  collect  on  the  glass  surface  for  a  long  time.  This 
creates a risk of white efflorescence (glass disease) which 
may result in the deterioration of energy generation. 

12.  Do not install the PV module horizontally. It may cause dirt 

or white efflorescence (glass disease) due to water. 

13.  Do not cover the water drain gap of the frame. There is a 

risk  of  frost  damage  when  the  frame  is  filled  with  water 
cumulation. 

14.  If there is a risk of sliding snow, an appropriate measure 

has to be taken so that PV module frames on lower edge 
of PV modules will not be damaged. 

15.  Do  not  expose  PV  module  to  sunlight  concentrated  with 

mirrors, lenses or similar means. 

16.  Turn off inverters and circuit breakers immediately, should 

a problem occur. 

17.  In case the glass surface of a PV module is broken, wear 

goggles and tape the glass to keep the broken pieces in 
place. 

18.  A  defective  PV  module  may  generate  power  even  if  it  is 

removed from the system. It may be dangerous to handle 
the PV module while exposed to sunlight. Place a defective 
PV module in a carton so PV cells are completely shaded. 

19.  In  case  of  series  connection,  the  maximum  open  circuit 

voltage must  not be  greater than the specified maximum 
system voltage. The voltage is proportional to the number 
of modules in series. In case of parallel connection, please 
be sure to take proper measure (e.g. fuse for protection of 
PV  module  and  cable  from  over  current,  and/or  blocking 
diode for prevention of unbalanced strings voltage) to block 
the reverse current flow. The current may easily flow in a 
reverse direction. 

20.  Keep PV modules away from children. 
 

HANDLING SAFETY 

1. 

Do  not  cause  an  excessive  load  on  the  surface  of  PV 
module or twist the frame. The glass surface or cells in the 
PV module can easily break. 

2. 

Do not stand or step on the PV module. The surface glass 
of PV module is slippery. Besides, the weight may cause 
PV module damage. 

3. 

Do not hit or put excessive load on the glass or back sheet. 
The PV cell is very thin and can be easily broken. 

4. 

Do not scratch or hit at the back sheet. The back sheet is 
vulnerable. 

5. 

Do not damage the junction boxes or do not pull the cables. 
The junction boxes can crack and break. 

6. 

Never touch junction box or the end of output cables with 
bare hands when the PV module is irradiated. Cover the 
surface  of  PV  module  with  cloth  or  other  suitable 
sufficiently opaque material to isolate the PV module from 
incident  light  and  wear  rubber  gloves  when  handling  the 
wires to avoid electric shock. 

7. 

Do not scratch the output cable or bend it with force. The 
insulation  of  output  cable  can  break  and  may  result  in 
electricity leakage or shock. 

8. 

Do not pull the output cable excessively. The output cable 
may unplug and cause electricity leakage or shock. 

9. 

Do  not  drill  holes  in  the  frame.  It  may  compromise  the 
frame strength and cause corrosion. 

10.  Do not scratch the insulation coating of the frame (except 

for  grounding  connection).  It  may  cause  corrosion  of  the 
frame or compromise the framework strength. 

11.  Do not touch the PV module with bare hands. The frame 

of PV module has sharp edges and may cause injury. 

12.  Do not drop PV module or allow objects to fall down on the 

PV module. 

13.  Do not concentrate sunlight artificially on the PV module. 
14.  Do not hold the PV module on one side.  The frame may 

bend or twist. Hold the PV module at opposite sides. 

 

INSTALLATION SAFETY 

1. 

Always  wear  protective  head  gear,  insulating  gloves  and 
safety  shoes  (with  rubber  soles).  Do  not  wear  metallic 
jewelry to prevent electric shock during installation. 

2. 

Keep the PV module packed in the carton until installation. 

3. 

Do  not  touch  the  PV  module  unnecessarily  during 
installation.  The  glass  surface  and  the  frames  get  hot. 
There is a risk of burn, or electric shock. 

4. 

Do not work under rain, snow or windy conditions. 

5. 

Use dry insulated tools. 

6. 

Do not drop tools or hard objects on PV modules 

7. 

When working at heights, wear a safety belt and take care 
not to drop any items (e.g., PV module or tools). 

8. 

Make  sure  flammable  gases  are  not  generated  near  the 
installation site. 

9. 

Completely cover the PV module surface with an opaque 
material during PV module installation and wiring. 

10.  Plug  in  the  connector  tight  and  ensure  the  wiring  work.

 

Make  sure  that  the  connectors  have  been  locked  by  a 
snap-in  latch.  Any  treatments  over  the  connectors  which 
may allow to unlock the snap-in latch shall not be done. 

11.  Due to the risk of electrical shock, do not perform any work 

Summary of Contents for NU-JD545

Page 1: ...s e g snow stopper to avoid possible damage 13 Periodically remove any overhanging snow and or ice from the PV module framework as it may cause deformation of the PV module frame GENERAL INSTRUCTIONS 1 INTRODUCTION This INSTALLATION MANUAL contains essential information for the electrical and mechanical installation that you must know before installing SHARP PV modules This also contains safety in...

Page 2: ...ters and circuit breakers immediately should a problem occur 17 In case the glass surface of a PV module is broken wear goggles and tape the glass to keep the broken pieces in place 18 A defective PV module may generate power even if it is removed from the system It may be dangerous to handle the PV module while exposed to sunlight Place a defective PV module in a carton so PV cells are completely...

Page 3: ...maximum output power when it faces the sun directly 5 degrees or more is recommended for the tilt angle of the PV module for the maintenance See 9 Maintenance For the standalone systems with a battery where the PV modules are attached to a permanent structure the tilt angle of the PV modules should be determined to optimize the performance when the sunlight is the scarcest In general if the electr...

Page 4: ... wiring and the state of the jacket of wires occasionally The PV modules is equipped with anti reflective coating glass do not touch the glass since finger prints or stains will easily mark If dirt build up becomes excessive clean the glass surface with water only INSTALLATION INSTRUCTIONS PHOTOVOLTAIC MODULES 1 INSTALLATION Mounting Using Clamps The PV modules can be mounted with clamps clips as ...

Page 5: ...cal conditions These values are calculated under the condition of Voc at 40 C Under normal conditions a PV module is likely to experience conditions that produce more current and or voltage than reported at Standard Test Conditions Accordingly the values of Isc and Voc marked on this PV module should be multiplied by a factor of 1 25 when determining component voltage ratings conductor current rat...

Page 6: ...Pa 300 e 435 2 400Pa 2 400Pa 300 e 435 1 600Pa 1 600Pa Table A3 1 Test load by using Bolt Holes see Fig A3 Table A3 Design load by using Bolt Holes see Fig A3 bolts nuts Clip center position position of using holes downward force upward force position of using holes downward force upward force 4 points at b hole 5 400Pa 2 400Pa 4 points at b hole 3 600Pa 1 600Pa The test load has been calculated w...

Reviews: