background image

MTA14004 

 

 

8 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Fig.2 The back view of the module 

 

Summary of Contents for NS-F128G6

Page 1: ...n t reproduce or cause anyone reproduce them without Sharp s consent 3 Please obey the instructions mentioned below for actual use of this module 1 Main applications of the modules as follows Grid connected PV systems Telemeter system Terminal Village electrification etc 2 Please take proper steps in order to maintain reliability and safety in case this module is used for the uses mentioned below ...

Page 2: ...Revision Record No DATE CHANGE PAGE SIGNATURE Approved by Checked by Prepared by March 26th 2014 First Issue ...

Page 3: ...rement of photovoltaic current voltage characteristics IEC 60904 3 Photovoltaic devices Part 3 Measurement principles for terrestrial photovoltaic PV solar devices with reference spectral irradiance data IEC 60904 9 Photovoltaic devices Part 9 Solar simulator performance requirements JIS C8939 Amorphous solar PV modules JIS C8991 Thin film terrestrial photovoltaic PV modules Design qualification a...

Page 4: ...tor Model KB1JS01PG2 KB1JS01SG2L 4 3 4 Mass The typical mass of modules is shown in the appended data sheet 4 3 5 Dimension The typical size of modules 1402mm 1001mm 24mm The tolerance in dimension of module is shown in Fig 1 and Fig 2 4 4 Identification and product marking The nameplate design as the identification and product marking is shown in Fig 3 4 5 Appearance The followings shall be consi...

Page 5: ...module is to be outdoor put an appropriate cover so it would not be hit by rain directly Do not store the module in a storage where condensation many occurs 4 6 1 2 Operating temperature of solar cells The operating temperature of solar cells should be from 40 to 90 4 6 1 3 Storage humidity The storage humidity of the modules should be less than 90 of relative humidity 4 6 2 Electrical performance...

Page 6: ...test at 2400Pa in accordance with IEC 61646 Ed 2 4 6 3 2 Withstanding the impact of hailstone This module satisfies the requirement of hailstone test in accordance with IEC 61646 Ed 2 4 6 3 3 Robustness of termination This module satisfies the requirement of robustness of terminations in accordance with IEC 61646 Ed 2 5 SHIPPINGTEST Each shipping lot shall successfully pass the shipping tests belo...

Page 7: ...ith brush the coil is most likely to be damaged 7 2 Handling 1 Never touch the output terminals with bare hands when the module is irradiated Cover the surface of the module by sufficiently thick cloth or something suitable to prevent incident light and handle the output terminals with rubber gloved hands not to receive the electric shock 2 Do not drop tools or hard things on the front cover back ...

Page 8: ...ed KB1JS01PG2 KB1JS01SG2L can be used in accordance with IEC61646 Ed 2 and IEC617730 Ed 1 as shown Fig C 15 Please keep the open circuit condition in the PV modules before completing the electrical wiring of PV system 7 4 Operation 1 When a part of the modules is shadowed the hot spot may be caused Therefore do not shadow cells 2 The modules shall be maintained by qualified personnel 3 The electri...

Page 9: ...MTA14004 7 Fig 1 The front view of the module ...

Page 10: ...MTA14004 8 Fig 2 The back view of the module ...

Page 11: ...MTA14004 9 Fig 3 The nameplate design 10 5 Pmax 90mm 50mm NS F128G6 NS F128G6 128W 59 8V 3 45A 45 4V 2 82A 1000V 5A caution Potential electrical hazard ...

Page 12: ...arton box specifications Type A Banding strap Pallet Wood or Steel Corner Pad Resin Top Corner Carton Stretch film Cushioning Foamed Styrol Corner Angle Steel Brace Steel Screw Steel 1460 mm 1080 mm 1940 mm 970 mm Pallet Wood or Steal ...

Page 13: ...MTA14004 11 Fig 5 The shipping carton box specifications Type B NS F128G6 NS F128G6 The printing design of top cover ...

Page 14: ...MTA14005 Ⅰ 1 DATA SHEET of PV module NS F128G6 ...

Page 15: ...Cable PV1Fcable2 5mmsq Length900mm Typ Connector JAE Connector Model No KB1 IP rating67 Ⅰ 3 ELECTRICAL CHARACTERISTICS The initial electrical characteristics at STC standard test conditions Irradiance 1000 Wm 2 with the AM1 5 spectral irradiance distribution Cell temperature 25ºC 2ºC is shown in Table I 1 and the nominal electrical characteristics at STC are shown in Table I 2 Rated electrical cha...

Page 16: ...oval IEC61646 Ed 2 These values represent the average value of the seasonal change shown in Fig I 1 Furthermore these characteristics of the installed module are changed according to installation environment like the ambient temperature After installing these modules outdoors the maximum power declines 10 or more from an initial value within several days Then the maximum output value is changed ac...

Page 17: ...plication Class A 4 years Date of system installation February 1st 0 0 0 2 0 4 0 6 0 8 1 0 1 2 0 200 400 600 800 1000 1200 1400 cumulative exposure time in days Normalized Pmax Relative to nominal Pmax Nominal value 1st month Date of system installation February 1st 0 0 0 2 0 4 0 6 0 8 1 0 1 2 0 5 10 15 20 25 30 cumulative exposure time in days Normalized Pmax Relative to nominal Pmax Nominal valu...

Page 18: ...ch module is not necessarily in agreement with the characteristic shown below 1 Short circuit current Open circuit voltage Maximum power vs Irradiance Fig Ⅰ 2 0 10 20 30 40 50 60 70 80 90 100 110 120 0 200 400 600 800 1000 Relative Voc Isc Pmax Irradiation intensity W m2 Module temperature 25 Fig Ⅰ 2 Short circuit Current Open circuit Voltage vs Irradiance Characteristics Voc Isc Pmax Relative Voc...

Page 19: ... Fig Ⅰ 3 Current Power versus Voltage Characteristics 0 0 0 5 1 0 1 5 2 0 2 5 3 0 3 5 0 10 20 30 40 50 60 Voltage V Current A 0 20 40 60 80 100 120 140 Power W 1000 W m 2 900 W m 2 800 W m 2 700 W m 2 600 W m 2 Power vs Voltage Current vs Voltage 500 W m 2 400 W m 2 300 W m 2 200 W m 2 100 W m 2 ...

Page 20: ...c and Pmax versus Module temperature Fig Ⅰ 4 Fig Ⅰ 4 Short circuit current Open circuit voltage Maximum power vs Moduletemperature Characteristics 0 20 40 60 80 100 120 50 25 0 25 50 75 100 Relative Isc Voc Pm Module Temperature Isc Voc Pm Relative Isc Voc Pm ...

Page 21: ...ation temperature at 800W m2 irradiance in the plane of module air temperature20ºC windspeed1m sandopencircuitcondition 6 Spectrum sensitivity The performance changes by the spectrum of the light irradiated The electrical characteristics shown in this specification are measured under the simulated sunlight with AM1 5 spectrum 7 Design of system system design should consider both initial values and...