TINSEA120MNZZ

Additional Item(s) Excluded from Warranty Coverage

Warranty coverage does not apply when:

  a)  The product is installed or repaired or serviced  in a manner that is contrary to Sharp’s Installation Manual;
  b)  The product is installed in a mobile or marine environment, 
  c)  The product is subjected to improper voltage or power surges or abnormal environmental conditions (such as acid rain or other pollution);
  d)  The components in the construction base on which the module is mounted are defective; 
  e)  External corrosion, mold discoloration or the like occurs;
  f)  The product has been moved from its original installation;
  g)  The model number or serial number of the product is altered, removed or rendered illegible. 
Sharp’s aggregate liability in connection with the Product, if any, shall not exceed the purchase price paid to Sharp for the Product or service which 
gave rise to the claim under the Limited Warranty. 

The repair, replacement of the Product, or the supply of additional Product does not cause the beginning of new warranty terms, nor shall the original 
warranty terms of this Limited Warranty be extended. Any replaced product shall become Sharp’s property

Where to Obtain Service:

Warranty service is available at a Sharp Authorized Service Center Dealer located in the United States. To find 
the location of the nearest Sharp Authorized Service Center Dealer, call Sharp toll free at 1-800 SOLAR06 
(800-765-2706). 
Call toll free at 1-800-765-2706 to obtain a Return Authorization Number and shipping instructions. Proof of 
Purchase will be required. 

What to do to Obtain Service:

Ship prepaid your Product to a Sharp Authorized Service Center Dealer. Be sure to have Proof of Purchase 
available. If you ship the Product, be sure it is insured and packaged securely. Sharp will not be responsible for 
damage incurred during transport.

YOUR S

H

A

RP

 DISTRIBUTOR

SOLIGENT

800-967-6917

www.soligent.

net

Summary of Contents for ND-255QCS

Page 1: ...case of a brushless motor the lock function may become active and the motor may be damaged 2 In the case of a brush type motor the coil may be damaged 6 Always use gloves when handling the module never touch the glass surface with bare hands GENERAL SAFETY 1 Wiring and grounding method of the frame of arrays shall comply with national regional and local codes laws and standards 2 PV modules should...

Page 2: ... or in a raceway to prevent movement of the interconnect cable over time Cable support should be done in a way to avoid the connector from scratching or impacting the back sheet of the module 11 Do not touch the terminal box and the end of the interconnect cables connectors with bare hands during installation or under sunlight regardless of whether the PV module is connected to or disconnected fro...

Page 3: ...electronics corp E69905 assembly consists of a slider base and 8 32 screw and hex nut screw and hex nut are parts in component of 1954381 2 1 Place the grounding onto the frame making sure that the screw straddles the grounding hole 2 Thread the hex nut onto the end of the screw tighten the nut Recommended torque is between 2 0 and 2 2 Nm 3 Insert the grounding wire into the wire slot Press down o...

Page 4: ... in the bottom of the frame and according to Figure 6 The module should be fastened with four 4 M8 5 16 bolts Recommended torque value is 12 5 Nm This mounting method is designed to a static load of 2400 Pa 50 1 lbs ft For your reference please use the washer specified as below for the minimum requirement We recommended parts of the following specifications 1 Spring washer 3 Bolt Material Stainles...

Page 5: ...ions Clamp Thickness Minimum mm Clamp Width Minimum mm Catch Width Minimum mm Support Width Minimum mm Option A 3 3 mm 38 mm 5 mm 10 mm Option B 3 0 mm 43 6 mm 5 mm 10 mm Figure 6 1640 0 mm 820 0 mm 558 8 mm minimum Figure 7 5 9 150 mm e 16 1 410 mm 5 9 150 mm s 16 1 410 mm Figure 8 Figure 9 ...

Page 6: ...r Vpmax 30 2 V 29 8 V 29 3 V Current at maximum power Ipmax 8 45 A 8 4 A 8 36 A Maximum System Voltage 600 V 600 V 600 V Minimum Blocking diode 15 A 15 A 15 A Series Fuse 15 A 15 A 15 A ND 250QCJ ND 245QCJ ND 240QCJ Maximum Power Pmax 250 0 W 245 0 W 240 0 W Open Circuit Voltage Voc 38 3 V 37 8 V 37 5 V Short Circuit Current Isc 8 9 A 8 90 A 8 75 A Voltage at maximum power Vpmax 29 8 V 29 3 V 29 3...

Page 7: ...years from date of purchase by the consumer the first 10 years at 90 minimum rated power output and the balance of 15 years at 80 minimum rated power output This warranty is transferable when product remains installed in original location at the time of product warranty registration This warranty does not apply to any alteration of the appearance of the Product that does not affect the performance...

Page 8: ...hall not exceed the purchase price paid to Sharp for the Product or service which gave rise to the claim under the Limited Warranty The repair replacement of the Product or the supply of additional Product does not cause the beginning of new warranty terms nor shall the original warranty terms of this Limited Warranty be extended Any replaced product shall become Sharp s property Where to Obtain S...