MD-MS702MK
– 11 –
: Digital EQ setting menu
: High-reflection pit section Digital EQ tap factor A, D
: setting
: High-reflection pit section Digital EQ tap factor B, C
: setting
: High-reflection pit section Autolevel slicer gain
: setting
: High-reflection pit section Autolevel slicer slice level offset
: setting
: Lows-reflection pit section Digital EQ tap factor A, D
: setting
: Low-reflection groove section digital EQ tap factor A, D
: setting
: Lows-reflection pit section Digital EQ tap factor B, C
: setting
: Low-reflection pit section Autolevel slicer gain
: setting
: Low-reflection pit section Autolevel slicer slice level offset
: setting
: Low-reflection groove section digital EQ tap factor B, C
: setting
: Low-reflection groove section Autolevel slicer gain
: setting
: Low-reflection groove section Autolevel slicer slice level offset
: setting
: Digital EQ-related other settings
: setting
PLAY
D E Q S E T
Digital EQ Setting
H Q 1
H Q 2
SKIP UP
SKIP DOWN
H S G
SKIP UP
SKIP DOWN
H S O
SKIP UP
SKIP DOWN
L Q 1
SKIP UP
SKIP DOWN
L Q 2
SKIP UP
SKIP DOWN
L S G
SKIP UP
SKIP DOWN
L S O
SKIP UP
SKIP DOWN
G Q 1
SKIP UP
SKIP DOWN
G S O
SKIP UP
SKIP DOWN
D Q R
SKIP UP
SKIP DOWN
G Q 2
SKIP UP
SKIP DOWN
G S G
SKIP UP
SKIP DOWN
* When the "STOP" button is pressed in specific menu, the TEST MODE STOP state is set.
* In specific state pressing the [DISP] key causes change to "focus setting menu".
* In the specific setting display state the setting change digit changes
when the [P-MODE] key is pressed.
1st digit (initial value)
2nd digit
P-MODE
P-MODE
* In the specific state the setting changes in the range of "0h to Fh"
when the [VOL UP/DOWN" key is pressed.
: Control setting menu
: Play start SD number, EEPROM version
: setting
: REC superposition, EL existence/nonexistence, move start minimum number,
high-speed jump over-run
: setting
: DC-IN existence/nonexistence judgment level, AC adapter judgment level,
built-in battery full judgment level
: setting
: Recording bit distribution parameter 0
: setting
: Recording bit distribution parameter 1
: setting
: Syncro level selection
: setting
: Dry cell exhaustion detection level setting 1
: setting
: Dry cell exhaustion detection level setting 2
: setting
: Built-in battery exhaustion detection level setting 1
: setting
: Built-in battery exhaustion detection level setting 2
: setting
: Intermittent servo restart accumulation sector number setting
: setting
: Control setting 2
: setting
: Control setting 3
: setting
: Control setting 4
: setting
: Control setting 5
: setting
: Control setting 6
: setting
PLAY
C T R L
Control Setting (record/playback machine)
C T 0
C T 1
SKIP UP
SKIP DOWN
P W L
SKIP UP
SKIP DOWN
R C 0
SKIP UP
SKIP DOWN
R C 1
SKIP UP
SKIP DOWN
S Y C
SKIP UP
SKIP DOWN
D R 1
SKIP UP
SKIP DOWN
D R 2
SKIP UP
SKIP DOWN
I N 1
SKIP UP
SKIP DOWN
I N 2
SKIP UP
SKIP DOWN
C T R
SKIP UP
SKIP DOWN
C T 2
SKIP UP
SKIP DOWN
C T 3
SKIP UP
SKIP DOWN
C T 4
SKIP UP
SKIP DOWN
C T 5
SKIP UP
SKIP DOWN
C T 6
SKIP UP
SKIP DOWN
Continued to
the next page
SKIP UP
SKIP DOWN