LC-70LE835E/RU, 836E/S, 838E
6 – 20
LED flashing timing chart at the time of the error
1) Low-speed blinking
2) Lamp failure details (Low-speed blinking: Flashes once + High-speed blinking)
3) Power failure details (Low-speed blinking: Flashes twice + High-speed blinking)
Error type
Expression of Central Icon LED
Lamp failure
low-speed blinking
Flashes once
H: ON
L: OFF
Refer to “Lamp failure details”.
LOW/High blinking by pressing the [MENU] key on the remote
control.
Power failure
low-speed blinking
Flashes twice
H: ON
L: OFF
Refer to “Power failure details”.
LOW/High blinking by pressing the [MENU] key on the remote
control.
Communication
failure with main CPU
low-speed blinking
Flashes 3 times
H: ON
L: OFF
Refer to “Communication failure details”.
LOW/High blinking by pressing the [MENU] key on the remote
control.
Communication line failure or main CPU communication failure.
Others
low-speed blinking
Flashes 4 times
H: ON
L: OFF
Refer to “Other failure details”.
LOW/High blinking by pressing the [MENU] key on the remote
control.
Error type
Expression of Central Icon LED
Note: Pins are monitor microprocessor pins unless otherwise
specified (IC2001).
Lamp failure
Flashes once
(High speed)
H: ON
L: OFF
LAMP_ERR (19pin): Abnormal H.
Confirmed after 8 consecutive detections at 64ms intervals
(detected only when the backlight is on).
NOTE: After 5 detection counts, the lamp cannot be activated
except in the monitoring process.
To confirm the problem, “Lamp Error detection off-mode”
is prepared.
This mode compulsorily starts the set disregarding the
count.
Please refer to [7. Lamp Error detection (ADJUSTMENT
PROCEDURE)]
Error type
Expression of Central Icon LED
Note: Pins are monitor microprocessor pins unless otherwise
specified (IC2001).
PS_ON
AC_DET failure
Flashes once
(High speed)
H: ON
L: OFF
AC_DET (28pin): Abnormal (L).
If error is detected during start-up or operation, the power is turned
on again by interrupt handling (instantaneous blackout process-
ing).
SM_POW
Main 13V failure
Flashes twice
(High speed)
H: ON
L: OFF
DET_13V (32pin): Abnormal (L). Main 13V is not applied.
If error is detected during start-up or operation, the power is turned
on again by polling.
D_POW
Digital 3.3V failure
Flashes 3 times
(High speed)
H: ON
L: OFF
DET_D3V3 (33pin): abnormal (L). Digital 3.3V is not applied.
If error is detected during start-up or operation, the power is turned
on again by polling.
PANEL_POW
Panel 12V failure
Flashes 5 times
(High speed)
H: ON
L: OFF
DET_PNL12V (34pin): abnormal (L). DET_PNL12V is not applied.
Detection starts after receiving command from Panel Power ON.
The power is turned off by polling.
100ms
400ms
1.6sec
Summary of Contents for LC-70LE835E/RU
Page 4: ...LC 70LE835E RU 836E S 838E iii End of life disposal End of life disposal ...
Page 7: ...LC 70LE835E RU 836E S 838E 1 2 2 SPECIFICATIONS LC 70LE838 ...
Page 9: ...LC 70LE835E RU 836E S 838E 2 2 ...
Page 10: ...LC 70LE835E RU 836E S 838E 2 3 LC 70LE835E RU 836E S ...
Page 11: ...LC 70LE835E RU 836E S 838E 2 4 ...
Page 12: ...LC 70LE835E RU 836E S 838E 2 5 LC 70LE838E ...
Page 13: ...LC 70LE835E RU 836E S 838E 2 6 ...
Page 14: ...LC 70LE835E RU 836E S 838E 2 7 2 OPERATION MANUAL ...
Page 72: ...LC 70LE835E RU 836E S 838E 8 4 ...
Page 79: ...LC 70LE835E RU 836E S 838E ...