10)OSD display [ON SCREEN DISPLAY]
11)Start mode [INPUT MODE START]
Example of option: “NORMAL”
“TVD (002TV)”, “INPUT1”, “INPUT2”, “INPUT3”, “PC”, “HDMI1”, “HDMI2”, “HDMI3”, “INPUT8”
12)Input fixed [INPUT MODE FIXED]
13)Speaker ON/OFF selection [LOUD SPEAKER]
14)Remote control path through [RC PATH THROUGH]
Option
“YES”, “NO” or “LIMITED” (loop enabled)
“LIMITED” is looped only in case of need (destination).
Default
YES
Function
• When set to “NO”, the following OSD is not displayed.
Registration, setting, adjustment menu, channel call, volume bar, and input select.
• When set to “LIMITED”, only a part of OSD is not displayed.
Key which may be
enabled (Example of the
confusing key)
* OK if simple input select occurs or the original state returns soon if left.
Key disabled when set
other than default
(example)
* The keys by which visibility of the screen or sound is changed cannot be used.
STILL IMAGE, SCREEN DISPLAY, OFF TIMER, AV POSITION, BRIGHTNESS SENSOR, SCREEN SIZE
SELECT, AUTO PRESET, MANUAL MEMORY, IMAGE SELECT, SOUND SELECT, LANGUAGE
Remarks
• When set to “NO”,
The set time of OFF TIMER “SLEEP” is cleared.
When the card function is set to “NO”, all the functions including input select and direct keys are invalid.
Option
“NORMAL” or “Input source 1 (input selection or channel)”
•
•
•
(loop enabled)
Default
NORMAL
Function
The input source or channel to start when turning on the power is set.
If “NORMAL”, the content of the last memory is followed.
Remarks
• When set other than “NORMAL”,
Display of the channel setting menu and channel setting operation are prohibited.
• When set to “NORMAL”, “START MODE FIXED” is set to “VARIABLE” and selection is prohibited.
Option
“VARIABLE” “FIXED”, “AC CTRL” or “AC/RC CTRL” (loop enabled)
Default
VARIABLE
Function
When set to “FIXED”, switching to another channel or input is impossible after start-up in the set value of “INPUT
MODE START”.
When set to “AC CTRL”, the unit starts in the set value of “INPUT MODE START” in the case of the ACON only.
When set to “AC/RC CTRL”, the unit starts in the set value of “INPUT MODE START”.
Key disabled when set
To “FIXED” (example)
CHANNEL (
/
), DIRECT CHANNEL buttons, FLASHBACK, INPUT SELECT, TV/VIDEO, AUTO PRESET,
MANUAL MEMORY, i.LINK, DIRECT INPUT SELECT, ATV, DTV, EPG, RADIO
Remarks
• If the “START MODE” setting is “NORMAL”, this item cannot be set.
Set to “VARIABLE”.
• When set to “FIXED”
The channel setting menu and input selection menu in the menu are not displayed.
Option
“ON” or “OFF” (loop enabled)
Default
ON
Function
The sound from the speakers is not output even if the headphones are not used.
Remarks
• When the VOLUME UP/DOWN key is pressed, the mute icon is displayed for 4 seconds.
• For the MUTE key and sound-related keys, caution is displayed.
• For the headphones and monitor output sound, normal operation is possible.
Option
“OFF”, “ON: TV RCE” or “ON: TV RCD” (loop enabled)
Default
OFF
Function
The signal received by the remote control’s light-receiving section is output to the blank pin (9pin) of RS232C.
Exception
• Even in the case of “ON: TV RCD”, the PROCESS MODE, INSPECTION MODE and HOTEL MODE keys are
enabled.
• Even in the case of “ON: TV RCD”, all the keys are enabled while entering the PROCESS MODE, INSPECTION
MODE and hotel mode.
Remarks
• The model always outputting and that impossible to output exist due to the structure of the hardware.