30
LC-40LE730
LC-46LE730
6. White Balance Adjustment
7. White Balance Adjustment
Condition:
AV MODE=
Dynamic
(backlight at max.).
Select correct Inch setting (40”or 46”) in “INIT” menu.
Adjustments reference device:
Minolta CA-210
Adjustments target:
x=0.274, y=0.284
High: adjustments spec ±0.001, inspection spec: ±0.002
Low: adjustments spec ±0.002, inspection spec: ±0.004
1.
Press “▼” until selecting “GAMMA” option.
2.
Press “OK”.
3.
“GAMMA” menu appears.
4.
Press “▼” until selecting “MGAMMA RESET”.
5.
Press “►”, to restore default values.
6.
Hold the default value for “MGAMMA G1”.
(Note: next, try to get the (x, y) adjustments target, changing “MGAMMA R1” and
“MGAMMA B1” as follow).
7.
Press “▼” until selecting “MGAMMA R1”.
8.
Press “►” to enter “Internal Adjustments Pattern 1”.
9.
Press “◄ ►” until you obtain the desired value.
10.
Press “END” to return to previous menu.
11.
Press “▼” until selecting “MGAMMA B1”.
12.
Press “►” to enter “Internal Adjustments Pattern 1”.
13.
Press “◄ ►” until you obtain the desired value.
14.
Press “END” to return to previous menu.
(Note: In case of not being possible to achieve the desired (x, y) target, try to get it by
changing also the “MGAMMA G1”)
15.
Press “▼” until selecting “MGAMMA R2”.
16.
Press “►” to enter “Internal Adjustments Pattern 2”.
17.
Repeat from step 6 to 14 for the “MGAMMA R2” and “MGAMMA B2”.
18.
Press “▼” until selecting “MGAMMA R3”.
19.
Press “►” to enter “Internal Adjustments Pattern 3”.
20.
Repeat from step 6 to 14 for the “MGAMMA R3” and “MGAMMA B3”.
21.
Press “▼” until selecting “MGAMMA R4”.
22.
Press “►” to enter “Internal Adjustments Pattern 4”.
23.
Repeat from step 6 to 14 for the “MGAMMA R4” and “MGAMMA B4”.
24.
Press “▼” until selecting “MGAMMA R5”.
25.
Press “►” to enter “Internal Adjustments Pattern 5”.
26.
Repeat from step 6 to 14 for the “MGAMMA R5” and “MGAMMA B5”.
27.
Press “▼” until selecting “MGAMMA R6”.
28.
Press “►” to enter “Internal Adjustments Pattern 6”.
29.
Repeat from step 6 to 14 for the “MGAMMA R6” and “MGAMMA B6”.
30.
Press “▼” until selecting “Commit”.
31.
Press “►”, to save the new values.
NOTE:
For activating the W/B flag, only is necessary to send the order “Commit”. After this action, the
“W” W/B flag will change to “1”.