background image

LC-13S1U-B

LC-13S1U-W

4

Precautions for using lead-free solder

1 Employing lead-free solder

"All PWBs" of this model employs lead-free solder. The LF symbol indicates lead-free solder, and is attached on
the PWBs and service manuals. The alphabetical character following LF shows the type of lead-free solder.
Example:

2 Using lead-free wire solder

When fixing the PWB soldered with the lead-free solder, apply lead-free wire solder. Repairing with conventional
lead wire solder may cause damage or accident due to cracks.
As the melting point of lead-free solder (Sn-Ag-Cu) is higher than the lead wire solder by 40°C, we recommend
you to use a dedicated soldering bit, if you are not familiar with how to obtain lead-free wire solder or soldering bit,
contact our service station or service branch in your area.

3 Soldering

As the melting point of lead-free solder (Sn-Ag-Cu) is about 220°C which is higher than the conventional lead
solder by 40°C, and as it has poor solder wettability, you may be apt to keep the soldering bit in contact with the
PWB for extended period of time. However, Since the land may be peeled off or the maximum heat-resistance
temperature of parts may be exceeded, remove the bit from the PWB as soon as you confirm the steady soldering
condition.
Lead-free solder contains more tin, and the end of the soldering bit may be easily corroded. Make sure to turn on
and off the power of the bit as required.
If a different type of solder stays on the tip of the soldering bit, it is alloyed with lead-free solder. Clean the bit after
every use of it.
When the tip of the soldering bit is blackened during use, file it with steel wool or fine sandpaper.

Be careful when replacing parts with polarity indication on the PWB silk.

Indicates lead-free solder of tin, silver and copper.

Lead-free wire solder for servicing

Part No,

Description

Code

ZHNDAi123250E

J

φ

0.3mm

250g(1roll)

BL

ZHNDAi126500E

J

φ

0.6mm

500g(1roll)

BK

ZHNDAi12801KE

J

φ

1.0mm

1kg(1roll)

BM

L

F a

Summary of Contents for LC-13S1UB

Page 1: ...to be used for after sales service only The contents are subject to change without notice LCD COLOR TELEVISION CONTENTS IMPORTANT SERVICE SAFETY PRECAUTION 2 SPECIFICATIONS 5 OPERATION MANUAL 6 DIMENSIONS 9 REPLACEMENT PARTS LIST 10 PACKING OF THE SET 13 Page OUTLINE The above model is based on the LC 13S2U S Its cabinet color and desktop stand has been redesigned This Service Manual covers the mo...

Page 2: ...tory recommended replacement parts shown in this service manual may create shock fire or other hazards WARNING 1 For continued safety no modification of any circuit should be attempted 2 Disconnect AC power before servicing BEFORE RETURNING THE RECEIVER Fire Shock Hazard Before returning the receiver to the user perform the following safety checks 1 Inspect all lead dress to make certain that lead...

Page 3: ...ectrocutions incendies radiations X ou autres accidents AVERTISSEMENT 1 N entreprendre aucune modification de tout circuit C est dangereux 2 Débrancher le récepteur avant toute réparation VERIFICATIONS CONTRE L INCEN DIE ET LE CHOC ELECTRIQUE Avant de rendre le récepteur à l utilisateur effectuer les vérifications suivantes 1 Inspecter tous les faisceaux de câbles pour s assurer que les fils ne so...

Page 4: ... which is higher than the conventional lead solder by 40 C and as it has poor solder wettability you may be apt to keep the soldering bit in contact with the PWB for extended period of time However Since the land may be peeled off or the maximum heat resistance temperature of parts may be exceeded remove the bit from the PWB as soon as you confirm the steady soldering condition Lead free solder co...

Page 5: ...language English French Spanish Power supply DC 12 V AC 110 240 V 50 60 Hz AC Adapter AC 125V MAX AC Cord Power consumption Weight Accessories Remote control Battery x2 Antenna cable AC adapter AC cord Cable clamp Operation manual LC 13S1U Model As a part of policy of continuous improvement SHARP reserves the right to make design and specification changes for product improvement without prior noti...

Page 6: ...he screen to the best viewable angle OPC sensor Remote control sensor OPC indicator Optical Picture Control The Optical Picture Control indicator lights up green when the BRIGHTNESS is set to AUTO POWER indicator A green indicator lights when the power is on and a red indicator lights when in the standby mode the indicator will not light when the main power is off Adjustable range S VIDEO INPUT ON...

Page 7: ...ENU Display the menu screen 14 CC Display Closed Caption subtitles 15 TV VIDEO Select a Liquid Crystal Television input source 16 FLASHBACK Return to the previous channel 17 Channel Select Set the channel 1 10 2 3 5 6 7 8 9 11 12 14 15 16 17 4 13 PREPARATION Batteries for the Remote Control Before using the LCD TV set for the first time install two AAA size batteries supplied When the batteries be...

Page 8: ...al If your external device has a component terminal COMPONENT connection is recom mended you can view high quality pictures Example DVD Player etc Playback from 480 progressive output for DVD and DTV is available Example VCR Laser disc player If your external device has an S video terminal S VIDEO connection is recom mended To COMPONENT terminal Connecting a VCR DVD player or a video camera AV IN1...

Page 9: ...23 32 323 1033 64 267 11 17 32 293 6 23 64 161 7 7 29 32 200 8 17 64 7 919 64 236 35 63 16 157 8 17 64 210 10 3 16 259 553 64 148 12 47 8 124 10 37 64 269 11 21 64 288 355 64 98 51 32 128 221 64 59 4 7 8 124 5 45 64 145 315 16 100 3 15 16 100 1 1 2 38 ...

Page 10: ...y Star Label AC 1 10 TLABZA459WJZZ J POP Label AB 2 CCABBA270WJ02 J Cabinet B Ass y AZ LC 13S1U B 2 CCABBA270WJ03 J Cabinet B Ass y AZ LC 13S1U W 2 1 Not Available Cabinet B 2 2 GLEGGA027WJSA J Rubber Leg x2 AF 2 3 HiNDPA544WJSA J Model Label LC 13S1U B AE 2 3 HiNDPA545WJSA J Model Label LC 13S1U W AE 2 4 JBTN A183WJKA J Operation Button AK 2 5 JBTN A186WJKA J Power Button AF 2 6 LANGF2155CEFW J R...

Page 11: ...6 5 20 A A 2 Main PWB Sub PWB 7 12 8 14 25 18 9 17 24 21 11 13 D C E B H G I A O D K M L Q P 4 1 4 7 4 8 4 9 4 12 4 3 4 4 4 10 4 11 4 5 4 18 4 2 4 6 4 5 4 2 1 4 2 2 4 6 4 15 4 17 4 16 Q B C A A O P G H I 4 22 23 4 13 4 13 4 14 1 1 1 9 1 6 1 3 1 4 1 3 1 4 1 2 1 7 1 8 1 5 1 8 1 7 19 1 R C LED PWB A A K M E 3 3 3 3 1 3 2 3 1 3 3 1 2 3 1 1 10 1 10 ...

Page 12: ...le 50 pin AU SC2001 SC3401 PACKING PARTS NOT REPLACEMENT ITEM SPAKCA853WJZZ Packing Case LC 13S1U B SPAKCA854WJZZ Packing Case LC 13S1U W SPAKFA374WJZZ Packing Material Accessories SPAKPA213WJZZ Wrapping Paper SPAKXA297WJZZ Buffer Material SSAKA0160CEZZ Polyethylene Bag TLABK0001TAZZ Carton Label SUPPLIED ACCESORIES 16 XBBS930P05000 J Screw x2 LC 13S1U B AA 16 XBBSN30P05000 J Screw x2 LC 13S1U W A...

Page 13: ...AAA size Battery 2pcs Packing Material Accessories SPAKFA374WJZZ AC Adapter UADP A044WJPZ AC Cord QACCDA023WJPA Wrapping Paper SPAKPA213WJZZ Buffer Material SPAKXA297WJZZ Buffer Material SPAKXA297WJZZ Infrared R C Unit RRMCGA174WJSB LC 13S1U B RRMCGA174WJSC LC 13S1U W Antenna Cable QCNWG0003CEPA Packing Case SPAKCA853WJZZ LC 13S1U B SPAKCA854WJZZ LC 13S1U W Carton Label TLABK0001TAZZ Not Replaceme...

Page 14: ...or transmitted in any form or by any means electronic mechanical photocopying recording or otherwise without prior written permission of the publisher SHARP CORPORATION AV Systems Group Quality Reliability Control Center Yaita Tochigi 329 2193 Japan TQ1781 S Jul 2004 Printed in Japan MI KG Design and Production Information Design Japan Production Japan ...