E-16
TROUBLESHOOTING
ERROR DISPLAY
If the error continues to occur, contact a Sharp Service Center.
DIGITAL
INDICATION
ERROR DETAILS
REMEDY
Fan motor error.
Temperature-humidity sensor error.
Unplug the unit, wait one minute, then plug he unit in
again.
SYMPTOM
REMEDY
(the following are not due to a malfunction)
Odor and smoke persists.
• The air may have been dirty when the unit was plugged in.
Unplug the unit, wait one minute, and then plug the unit in again.
The Filter Indicator Light is on.
• Check the filters. If they appear to be extremely dirty, clean or
replace them. (Ref. E-11,E-12,E-13,E-14,E-15)
• Dirty or clogged dust sensor openings interfere with sensor
operation. Gently clean the back panel.
(Ref. E-11).
• The unit may make clicking or ticking sounds when it is
generating
ions.
• Check to see if the filters are extremely dirty.
• Clean or replace the filters.
• Plasmacluster Air Purifiers emit small traces of ozone that can
produce an odor.
• Check to see if the unit is installed in a location that makes it
difficult for the sensors to detect cigarette smoke.
• Check to see if the dust sensor openings are blocked or clogged.
If they are blocked or clogged, clean the back panel.
(Ref. E-11)
• Whenever replacing the filters, connect the power cord to an
outlet and then press the Filter Reset Button.
• Check to see if the Lights OFF Mode is selected. If it is selected,
press the Light ON/OFF Button to turn the indicator lights on.
(Ref.
E-9)
・
Check to see if the SLEEP mode is selected. (Ref. E-8)
• Clean the Humidifying Tray. Make sure that the unit is on a level
surface.
• Check to see if the Humidifying Tray is correctly installed. Check
the Humidifying Filter.
• If the Humidifying Filter is extremely dirty, clean or replace it.
(Ref. E-12, E-13, E-15).
• Humidification amount gets lower when humidity reaches to the
proper amount (55 ~ 65%) by the actuation of humidity sensor in
the case of fan speed automatic.
• There is a difference in the humidity level within the same room.
• The sensor have different measurement parameters.
• If the monitor indicates TEMPERATURE, press the Display Select
Button. (Ref. E-9)
• The Dust Sign lights automatically change color when the dust
sensor detect impurities.
The Dust Sign light is green even
when the air is not clean.
The Dust Sign light is orange or red
even when the air is clean.
The unit makes a clicking or ticking
sound.
Air discharged from the unit has an
odor.
The unit does not operate when
cigarette smoke is in the air.
The Dust Sign lights are turned off.
The Humidify Light does not light off
when the Humidifying Tray is empty.
The water level in the Humidifying
Tray does not decrease or decreases
slowly.
The Dust Sign lights change color
frequently.
There is a discrepancy between the
unit’s Humidity Monitor and another
hygrometer in the room.
Before calling for service, review the troubleshooting chart below to make sure
that the problem is not a unit malfunction.
OM_KC-F30TA_EN.indd E-16
OM_KC-F30TA_EN.indd E-16
4/7/2559 BE 11:04 AM
4/7/2559 BE 11:04 AM