E-17
SPECIFICATIONS
Power supply
220-240V 50
-60
Hz
Fan Speed Adjustment
MAX
MED
SLEEP
CLEAN AIR
Fan Speed (m
3
/hour)
180
125
52
Rated Power (W)
27
12
4.1
Noise Level (dBA)
48
38
21
CLEAN AIR
&HUMIDIFY
Fan Speed (m
3
/hour)
180
125
52
Rated Power (W)
27
12
4.1
Noise Level (dBA)
48
38
21
Humidification (mL/hour)*1
350
280
140
Recommended Room Size (m
2
)*2
~21
High density Plasmacluster ion recommended room size (m
2
)*3
~17
Humidifying Tray Capacity (L)
1.8
Sensors
Dust / Temperature & Humidity
Filter type
Dust collection
HEPA *4
Deodorization
Deodorizing
Cord Length (m)
2.0
Dimensions (mm)
380 (W) × 197 (D) × 570 (H)
Weight (kg)
7.2
*1 • The amount of humidification changes in accordance with indoor and outdoor temperature and
humidity.
The amount of humidification increases as temperatures rises or humidity decreases.
The amount of humidification decreases as temperatures decrease or humidity rises.
• Measurement Conditions : 20 ºC, 30 % humidity (JEM1426)
*2 • The recommended room size is appropriate for operating the unit of maximum fan speed.
• The recommended room size is an area in which a given amount of dust particles can be removed
in 30 minutes.
*3 • Room size in which approximately 7000 ions per cubic centimeter can be measured in the center of
the room when the unit is placed next to a wall, is running at maximum settings, and is at a height
of approximately 1.2 meters from the floor.
*4 • The filter removes more than 99.97% of particles at least 0.3-microns in size. (JEM1467)
Standby Power
When the unit’s power plug is inserted in a wall outlet it consumes about 0.9 watts of standby power in order to
operate electrical circuits.
To conserve energy, unplug the power cord when the unit is not in use.
ERROR DISPLAY
If the error continues to occur, contact a Sharp Service Center.
DIGITAL
INDICATION
ERROR DETAILS
REMEDY
Fan motor error.
Temperature-humidity sensor error.
Unplug the unit, wait one minute, then plug he unit in
again.
TROUBLESHOOTING
SYMPTOM
REMEDY
(the following are not due to a malfunction)
Odor and smoke persists.
• The air may have been dirty when the unit was plugged in.
Unplug the unit, wait one minute, and then plug the unit in again.
The Filter Indicator Light is on.
• Check the filters. If they appear to be extremely dirty, clean or
replace them. (Ref. E-11,E-12,E-13,E-14,E-15)
• Dirty or clogged dust sensor openings interfere with sensor
operation. Gently clean the back panel. (Ref. E-11).
• The unit may make clicking or ticking sounds when it is
generating ions.
• Check to see if the filters are extremely dirty.
• Clean or replace the filters.
• Plasmacluster Air Purifiers emit small traces of ozone that can
produce an odor.
• Check to see if the unit is installed in a location that makes it
difficult for the sensors to detect cigarette smoke.
• Check to see if the dust sensor openings are blocked or clogged.
If they are blocked or clogged, clean the back panel. (Ref. E-11)
• Whenever replacing the filters, connect the power cord to an
outlet and then press the Filter Reset Button.
• Check to see if the Lights OFF Mode is selected. If it is selected,
press the Light ON/OFF Button to turn the indicator lights on.
(Ref. E-9)
・
Check to see if the SLEEP mode is selected. (Ref. E-8)
• Clean the Humidifying Tray. Make sure that the unit is on a level
surface.
• Check to see if the Humidifying Tray is correctly installed. Check
the Humidifying Filter.
• If the Humidifying Filter is extremely dirty, clean or replace it.
(Ref. E-12, E-13, E-15).
• Humidification amount gets lower when humidity reaches to the
proper amount (55 ~ 65%) by the actuation of humidity sensor in
the case of fan speed automatic.
• There is a difference in the humidity level within the same room.
• The sensor have different measurement parameters.
• If the monitor indicates TEMPERATURE, press the Display Select
Button. (Ref. E-9)
• The Dust Sign lights automatically change color when the dust
sensor detect impurities.
The Dust Sign light is green even
when the air is not clean.
The Dust Sign light is orange or red
even when the air is clean.
The unit makes a clicking or ticking
sound.
Air discharged from the unit has an
odor.
The unit does not operate when
cigarette smoke is in the air.
The Dust Sign lights are turned off.
The Humidify Light does not light off
when the Humidifying Tray is empty.
The water level in the Humidifying
Tray does not decrease or decreases
slowly.
The Dust Sign lights change color
frequently.
There is a discrepancy between the
unit’s Humidity Monitor and another
hygrometer in the room.
Before calling for service, review the troubleshooting chart below to make sure
that the problem is not a unit malfunction.
Information on Disposal
This product should not be disposed of in a general waste bin as it contains materials that should be recycled,
which is good for the environment.
If you are in doubt about the correct disposal method, contact your local counsil.
KC-F30J_EN.indd 17
2018/05/24 13:25:03