32
KB-5121KS/K/W
Control Knobs
Retainers
Glass Key Deco
Indicator Lamps
Lens
GND Deco Screw
COOK TOP / MICROWAVE DRAWER DISASSEMBLY
Fig. 1
1. Before removing Control Panel, take measures to protect the
Cook Top surface and keep Microwave Drawer open
to prevent scratches.
2. Remove all Control Knobs
(Fig 1)
.
3. Unscrew all Retainers
(Fig 1)
.
4. Unscrew Glass Key Deco screw (1)
(Fig 1)
.
5. Carefully lift Glass Key Deco and unhook
Indicator Lamp from Lens
(Fig 1)
.
6. Remove all screws from Control Panel Mold
(Fig 2)
.
7. Slide Control Panel Mold to left (to unlock) and lift
(Fig 2)
.
8. Remove Gasket from Key Fixing Angle
(Fig 3)
.
unscrew (4) screws holding key fixing mold.
9. Lift Key Fixing Mold and carefully unhook all Molex’s,
ground wire and C/P wiring
(Fig 3).
WARNING: Follow all safety precautions beginning on Page 2 before proceeding!
Control Panel Mold
Gasket
Key Fixing Angle
Fig. 2
Fig. 3
NOTE:
When reassembling, it is very important
that all Cook Top wires are tucked under the
Microwave cavity lip and secured with the RED
WIRE STRAP. The 240v harness can create
noise that can interfere with C/P function
(example: intermittent or no keyboard operation).
CAUTION: Before performing any of the disassembly, disconnect the power source!