20. USB connection is impossible.
Connect a properly working handset to the Data/USB cable
that is not recognized. Is it recognized?
Reinstall the driver and replace the USB cable to connect the
handset.
Is a communication with the handset established via SPST for
GX30?
IC106, IC502, and IC504 are defective.
Connect to a Data with the USB cable.
Is TP536 at “H”?
The signal line from CN502 pin 8 to IC106 pin 90 is short-cir-
cuited with GND. Or R566 is has come off.
Is 5 V or more applied to TP515?
CN502 is connected improperly.
Is Q503 pin 3 at “L”?
Q503 is defective.
Is 3 V or more applied to TP166?
IC103 or IC106 is defective.
IC106 and IC502 are defective.
NO
YES
NO
YES
NO
YES
NO
YES
NO
YES
NO
YES