background image

3

CAUTIONS CONCERNING 

OPERATION

• Do not block the air inlet or air outlet.

• Do not place the main unit near or on 

hot objects, such as stoves or heaters, 

or where it may come into contact with 

steam.

• Always operate the main unit in an 

upright position.

• Do not move the main unit when it is in 

operation.

• When moving the main unit, use the 

handle on the back of the main unit.

• If the main unit is on easily damaged 

flooring, an uneven surface, or thick-piled 

carpet, lift it up when moving.

• Do not operate the main unit without the 

filters properly installed.

• Do not wash and reuse the HEPA filter 

and the Deodorizing filter. 

Doing so will not improve filter 

performance and can also cause electric 

shock or operating malfunctions.

• Clean the exterior with a soft cloth only. 

Do not use volatile fluids or detergents. 

The main unit surface may be damaged 

or cracked with Benzine, paint thinner or 

polishing powder. In addition, the sensors 

may malfunction as a result.

• Do not scrub the Back Panel hard during 

its maintenance. 

INSTALLATION GUIDELINES

• Avoid locations where the sensors are 

exposed to direct wind.  

Doing so can cause the main unit to 

malfunction.

• Avoid locations where furniture, fabrics, 

or other objects can come in contact with 

the main unit and interfere with the intake 

and outtake of air.

• Avoid locations where the main unit 

is exposed to condensation or drastic 

changes in temperature. Appropriate 

room temperature is between 0 – 35 ºC.

• Place the main unit on a level and stable 

surface with sufficient air circulation.  

When placed on heavy carpet, the main 

unit may vibrate slightly. 

• Avoid locations that generate grease or 

oily smoke.  

Doing so can cause the main unit 

exterior to crack and the sensors to 

malfunction.

• The dust collecting ability of the main 

unit is effective even when the main unit 

is as close to 3 cm from the wall,the 

surrounding walls and floor may get dirty. 

Please place the main unit at a distance 

from the wall.  

The wall directly behind the air outlet 

may become dirty over time. When using 

the main unit for an extended period of 

time at the same location, periodically 

clean the walls adjacent to it. 

 

 

FILTER GUIDELINES

• Follow the instructions in this manual for 

proper filter care and maintenance.  

(Page 4)

FP-J50J_2nd.indd   3

FP-J50J_2nd.indd   3

2022/04/22   11:01:13

2022/04/22   11:01:13

Summary of Contents for FP-J50J

Page 1: ...in this technology mark indicates an approximate number of ions supplied into air of 1 cm3 which is measured around the center of a room applicable floor area at 1 2 m height above the floor when the product is placed close to a wall at the MED mode setting FP J50J_2nd indd 1 FP J50J_2nd indd 1 2022 04 22 11 01 12 2022 04 22 11 01 12 ...

Page 2: ...ng additional odors Depending on usage conditions and especially if the main unit is used in environments significantly more severe than a normal household these odors may become noticeable sooner than expected If these odors persist replace the filters NOTE The air purifier is designed to remove air suspended dust and the odors The air purifier is not designed to remove harmful gases such as carb...

Page 3: ...cluster TRAPS DUST Pre Filter traps dust and other large airborne particles DECREASES ODORS Deodorizing filter absorbs many common household odors REDUCES POLLEN MOLD HEPA filter traps 99 97 of particles as small as 0 3 microns FRESHENS Plasmacluster treats the air similar to the way nature cleans the environment by emitting a balance of positive and negative ions When air is drawn through the fil...

Page 4: ...gn objects into the air inlet or air outlet When removing the power plug always hold the plug and never pull on the cord Failure to do so can cause a short circuit resulting in electrical shock or fire Be careful not to damage the power cord Failure to do so can cause electric shock heat generation or fire Do not remove the plug when your hands are wet Do not use this main unit near gas appliances...

Page 5: ...ere the sensors are exposed to direct wind Doing so can cause the main unit to malfunction Avoid locations where furniture fabrics or other objects can come in contact with the main unit and interfere with the intake and outtake of air Avoid locations where the main unit is exposed to condensation or drastic changes in temperature Appropriate room temperature is between 0 35 ºC Place the main unit...

Page 6: ... cleaner attachment or similar tool Dust sensor Odor sensor FILTERS Tag HEPA Filter Deodorizing Filter CAUTION Gently remove dust from HEPA Filter and Deodorizing Filter with a vacuum cleaner attachment or similar tool Do not WASH in water and DRY in the sun The filters are fragile be careful not to apply too much force HEPA Filter Apply the maintenance only on the side with the tag Do not clean t...

Page 7: ... frequently if the product is used in a condition significantly severer than normal household use The Replace Filter indicator light will turn on after approximately 17 500 hours in sleep mode 2 years 24 hours 17 500 Filter life varies depend on the operation mode HEPA Filter materials Polypropylene Polyethylene Deodorizing Filter materials Polypropylene Polyester Activated carbon REPLACEMENT HEPA...

Page 8: ...ight white 11 Handle Press 3 sec Filter Reset Button Indicator Light orange 12 Dust Sensor Filter 13 HEPA Filter 4 MODE Button Indicator Light white 14 Deodorizing Filter Press 3 sec Plasmacluster Ion ON OFF Button 15 Back Panel Pre Filter 5 CLEAN ION SHOWER Button indicator Light white 16 Bottom Tabs Press 3 sec Light Control Button 17 Plug 6 POWER ON OFF Button 18 Power Cord 7 Light Sensor 19 Ai...

Page 9: ... maintain the quality of the filter it is installed in the main unit and packed in plastic bag Be sure to remove the plastic bag from the filter before using the main unit 1 Remove the Back Panel Pull 2 Remove the plastic bag from the Filter Do not operate the main unit without the filter Always be sure to remove the power plug from the wall outlet FP J50J_2nd indd 7 FP J50J_2nd indd 7 2022 04 22 ...

Page 10: ...nd quickly detects impurities and clean the air powerfully for 50 minutes The Plasmacluster Ion can not be turnes OFF When the operation finishes the main unit will return to the prior operation mode It is able to change the other mode and during this mode NOTE STOP AUTO SLEEP The fan speed is automatically controlled depending on the 3 detection Dust Odor Light The main unit will operate very qui...

Page 11: ...in the previous mode it was operated in NOTE 1 with the main unit ON 2 more than 3 sec AUTO DIM OFF AUTO Light automatically switches ON or OFF based on room brightness Room is bright light is ON Room is dark light is OFF OFF When set to OFF the DIM light illuminates for 8 seconds after operation starts and then the light turns off more than 3 sec Dust sensor Odor sensor If the power OFF Button is...

Page 12: ... turned off Check to see if the Lights OFF Mode selected Press for 3 seconds to light On Page 9 Check to see if the SLEEP mode is selected The Cleanliness Monitor Plasmacluster Ion Light are turned off automatically after the SLEEP mode is selected Smell from a new unit and or filter Immediately after removing the plastic bag a slight odor may occur This odor is not harmful for filter performance ...

Page 13: ... and is at a height of approximately 1 2 meters from the floor 5 The filter removes more than 99 97 of particles at least 0 3 microns in size according to standards of the Japan Electrical Manufacturers Association JEM1467 Standby Power When the main unit s power plug is inserted in a wall outlet it consumes standby power in order to operate electrical circuits To conserve energy unplug the power ...

Page 14: ... relevant legislation in the country of sale WARRANTY PERIODS Air Purifier 12 months IMPORTANT NOTICE This warranty applies only to products sold in Australia New Zealand WARRANTY Consumer Electronic Products Australian customers Our goods come with guarantees that cannot be excluded under the Australian Consumer Law You are entitled to a replacement or refund for a major failure and for compensat...

Page 15: ...ILER OR CALL FOR LOCATION ENQUIRIES WITHIN AUSTRALIA REGARDING YOUR LOCAL SHARP APPROVED SERVICE CENTRE Customer service helplines 1300 742 770 calling within Australia Monday Saturday 9am 6pm Open Monday to Saturday except on public holidays Distributed by Tempo Aust Pty Ltd PO Box 132 Frenchs Forest NSW 1640 Australia info tempo org For an electronic copy of this manual please contact our after ...

Page 16: ...TINS B305KKRZ 22E 2 SHARP CORPORATION OSAKA JAPAN FP J50J_2nd indd 14 FP J50J_2nd indd 14 2022 04 22 11 01 49 2022 04 22 11 01 49 ...