2. Installation procedure

1) Turn over the drawer bottom side and remove rubber footing at

two to locations.

2) Fasten the bracket together with the rubber footing using the pand

hand screw.

Pay attention for the installing direction of the bracket that the pan
head screw can be inserted properly into the bracket.

Fig. 1

3) Fastening on the table:

Secure the fixing Bracket using the screw (Fig. 2).

If the thickness of the table is less than 15mm, bore a 4.5mm hole
in the table and fasten it with the screw (XBPSD40P22000 - 4pcs.)
and nut (XNESD40-32000 - 4pcs.).

Fig. 2

CHAPTER 9. SHIELD PLATE KIT:

DKIT-8666BHZZ (Only
for ER-A330)

1. Component list

No.

PARTS CODE

DESCRIPTION

Q’TY

1

LCHSM6705BHZZ

SHIELD PLATE

1

2

PGUMM6696BHZZ

GUM LEG

4

3

TLABH7054BHZZ

CAUTION CARD

4

4

XUBSD30P12X00

SCREW

1

5

XUBSD30P08000

SCREW

1

6

XJPSD30P12X00

SCREW

1

7

XJPSD40P12X00

SCREW

1

8

XHBSD30P08000

SCREW

3

9

LBSHC0004AGZZ

CLAMP

1

2. Installation procedure

1) Remove the top cabinet.

2) Remove the bottom cabinet.

3) Install the shield plate 

1

 to the bottom cabinet and fix it with ???

screws 

2

.

4) Attach four gum legs 

3

 to the shield plate and fix them with screws

4

.

5) Replace the top cabinet.

Pan head screw

Fixing bracket

Rubber footing

Cash drawer

Drawer bottom plate

Rubber footing

Fixing bracket

Pan head screw

Fixing bracket

Tapping screw

1

2

3

4

3

3

2

2

– 7 –

Summary of Contents for ER-A310

Page 1: ...A310 ER A330 4 CHAPTER 7 REMOTE DRAWER ER 04DW For ER A310 ER A330 5 CHAPTER 8 DRAWER FIXING KIT DKIT 8633RCZZ 6 CHAPTER 9 SHIELD PLATE KIT DKIT 8666BHZZ Only for ER A330 7 CHAPTER 10 ONE HOLE CASHIER KEY KIT 8 CHAPTER 11 KEY TOP KIT ER 11KT7 12KT7 22KT7 11DK7 51DK7 For ER A310 ER A330 8 CONTENTS SHARP CORPORATION This document has been published to be used for after sales service only The content...

Page 2: ...the wall outlet 4 While holding down JOURNAL FEED key turn to SRV position from SRV position Procedure 2 without SRV key 1 Turn the mode switch to the REG position 2 Ensure the batteries are not installed in the battery compartment and insert the plug into the outlet 3 The right most decimal point will blink for a few seconds 4 The register will sound three beeps 5 The register will display CHAPTE...

Page 3: ... the screw 3 and grounding wire 4 4 Separate the top cabinet and the drawer unit Note Transformer cable 5 and the drawer cable on the drawer unit are connected to the main PWB on the top cabinet Be careful when separating them from the drawer unit 5 Remove transformer cable 5 and drawer cable 6 from the main PWB 1 2 3 4 2 5 6 2 ...

Page 4: ... the drawer cable on the bottom cabinet are connected to the main PWB on the top cabinet Be careful when separating them from the bottom cabinet 5 Remove transformer cable 5 and drawer cable 6 from the main PWB CHAPTER 4 REMOVING THE BOTTOM CABINET Only for ER A330 1 ER A330 1 Remove the top cabinet 2 Remove the bottom cabinet 1 from the drawer unit 2 1 3 4 2 2 2 5 6 1 2 A B B A A B 3 3 ...

Page 5: ...grounding wire 4 5 Remove the printer unit 5 from the top cabinet CHAPTER 6 REMOVING THE MAIN PWB For ER A310 ER A330 1 ER A310 A330 1 Remove the top cabinet 2 Remove the printer unit 3 Remove the following connector cables from the main PWB Dry battery cable 1 Pop up display cable 2 Note The pop up cable is fixed with the holder not to make con tact with the heat radiating plate on the main PWB B...

Page 6: ... the resistor 1kΩ R80 and the transistor 2SC3784 Q20 to the main PWB 4 Replace the main PWB 5 Connect the drawer cable to the drawer connector on the main PWB 6 Use nippers to cut off drawer cable binding holder 1 on the trans cover and bind drawer cable 2 of the ER 04DW Screw 3 used in this case is an accessory of the ER 04DW 7 Use nippers to cot off the drawer cable split pin of the top cabinet ...

Page 7: ...round wire 4 of the ER 04DW on the standard drawer with screw 5 Screw 5 used in this case is an accessory of the ER 04DW 4 Operation test CHAPTER 8 DRAWER FIXING KIT DKIT 8633RCZZ The drawer fixing kit is used for securing the cash drawer when in stalling separately from the ECR main unit or remote drawer By using two of brackets the drawer box can be protected from drifting especially when it is ...

Page 8: ...TER 9 SHIELD PLATE KIT DKIT 8666BHZZ Only for ER A330 1 Component list No PARTS CODE DESCRIPTION Q TY 1 LCHSM6705BHZZ SHIELD PLATE 1 2 PGUMM6696BHZZ GUM LEG 4 3 TLABH7054BHZZ CAUTION CARD 4 4 XUBSD30P12X00 SCREW 1 5 XUBSD30P08000 SCREW 1 6 XJPSD30P12X00 SCREW 1 7 XJPSD40P12X00 SCREW 1 8 XHBSD30P08000 SCREW 3 9 LBSHC0004AGZZ CLAMP 1 2 Installation procedure 1 Remove the top cabinet 2 Remove the bot...

Page 9: ...emove the clerk cover A 1 from the top cabinet 3 Solder the clerk connector 5P 2 to the clerk switch body 3 4 Connect the clerk key cable 5P 4 to the clerk switch body 3 5 Attach the clerk angle 5 to the clerk switch body 3 and fix with screw 6 XJSSD26P08000 6 Install the clerk switch body 3 to the clerk cover B 7 then install it the top cabinet and fix with screws 8 XEBSD30P08000 7 Connect the cl...

Page 10: ...ote There are black spacers and white spacers Refer to the figure before for attaching them Attach the black spacer to the left lower side and the white spacer to the right lower side 3 ER 11DK7 ER 51DK7 ER 12KT7 ER 11KT7 ER 22KT7 ER 12KT7 ER 11KT7 ER 22KT7 9 ...

Reviews: