![Sharp CX-34G3 Service Manual Download Page 3](http://html.mh-extra.com/html/sharp/cx-34g3/cx-34g3_service-manual_1254301003.webp)
ADJUSTMENT PRECAUTIONS
n
SERVICE MODE
This model’s settings are adjusted in two different ways: through the
bus control and in the conventional analog
manner. The adjustment via the
bus control includes preset-only items and variable data.
1. Calling the service mode by the microprocessor
Set the switch
to the service mode position, and the microprocessor is put in the service mode
(adjustment through the
bus control).
Press the
UP/DOWN keys on the remote controller to select the modes one by one.
Press the
UP/DOWN keys on the remote controller to select the modes in the order opposite to the
above step
Using the VOLUME UP/DOWN keys on the remote controller, the data can be modified.
Set the switch
to the normal mode (OFF) position, and the microprocessor is put out of the
service mode.
2. Factory
Set the switch
to the service mode position and turn on the main power switch. Initial values are
automatically preset only when a new
is used (judgment with the first 4 bytes).
The initial data are preset as listed on pages 4 and 5.
Keep in mind that some settings should be modified, and the others should remain as preset.
Once the chassis has been put together, be sure to set the switch
to the service mode position
first and then turn on the main power switch (see the step
above). Turning on the power without
initializing the
may cause a flow of excess beam current.
3. The accompanying memory map
document for the
is for your
reference.
3-1
(1) Press the specific keys to change the modes as follows.
COLOUR ADJUST mode
60 Hz ADJUST mode
In the direction of arrow :
DOWN key
In the opposite direction :
UP key
m o d e
R-CUT OFF
G-CUT OFF
B-CUT OFF
,
HORIZONTAL mode
time out
time out
KEY
R-CUT OFF
G-CUT OFF
B-CUT OFF
R-DRIVE
B-DRIVE
HORIZONTAL mode
UP
DOWN
1
KEY
4
KEY
2
KEY
5
KEY
3
KEY
6
KEY
7 K E Y
KEY
8
KEY
0
KEY
9 K E Y
COLOUR ADJUST mode
V-AMP 50 Hz
V-LINE 50 Hz
S-CORRECT 50 Hz (V
V-PHASE 50 Hz
H-PHASE 50 Hz
START
STOP
R-Y (R-Y)
B-Y (R-Y)
In the direction of arrow :
DOWN key
In the direction of arrow :
DOWN key
In the opposite direction :
UP key
In the opposite direction :
UP key
l
The characters in parentheses appear on the on-screen display.
3-2