CVP09FX
2 – 5
[6] PRE-OPERATION CHECKS
[7] OPERATION MODE
1. Cool mode
2. Dehumidification mode
CAUTION
• Do not expose the signal receiver window to direct sunlight. This may adversely
affect its operation. If necessary, close the curtains to block out the sunlight.
• Use of a fluorescent lamp in the same room may interfere with transmission of the
signal.
• The unit may be affected by signals emitted from other remote controllers for
televisions, VCRs or other equipment used in the same room.
• Do not leave the remote control exposed to direct sunlight or near a heater. Pro-
tect the remote control from moisture and shock which can discolor or damage it.
Point the remote control towards the
units signal receiver window and
press the desired button.
A beep
will sound when the unit receives
the signal.
• Make sure nothing, such as curtains,
blocks the signal receiver window.
• The remote control operates up to 23
feet (7 meters) away.
HOW TO USE THE REMOTE CONTROL
To prevent the remote control from
being misplaced, hook it to the unit
when not in use.
When attached, to remove the remote
control from the unit, lift the remote
control up slightly and pull it out.
Remote control hook
1
Remove the battery cover at the
back of the remote control.
2
Insert batteries into the compart-
ment, making sure the
and
polarities are correctly
aligned.
¥ Lines will appear on the display
when batteries are properly in-
stalled.
3
Reattach the battery cover.
4
Press the RESET button using a
thin pointed implement.
NOTES:
¥ The battery should last approximately one year under normal use.
¥ When replacing the batteries, always change both batteries at the same time, and
make sure they are the same type.
¥ If the remote control does not operate normally after replacing the batteries, press
the RESET button using a thin pointed implement.
¥ If you will not be using the unit for a prolonged period, remove the batteries from
the remote control.
LOADING BATTERIES
Use two AAA (R03) batteries.
Battery cover
RESET
POWER PLUG CHECK
This air conditioner uses a fused power plug.
Always check the power plug before use.
1
Press the RESET button.
2
Insert the power plug into the wall socket.
3
Press the TEST button.
You will hear a CLICK if the circuit breaker is
functioning correctly.
4
Press the RESET button until you hear another
CLICK.
The circuit breaker is activated, power is supplied,
and the air conditioner is now ready for use.
Do not attempt to use the air conditioner if the above procedure is
impossible, as it is malfunctioning.
Disconnect the power plug and request service.
TEST
Drainage nozzle
Stopcock
Install the exhaust hose (See Page16), turn
the drainage nozzle to the CLOSE position,
and check the drainage nozzle is covered
with the stopcock.
1
Press the MODE button to select COOL
mode.
COOL
DEHUM
FAN
VENT
2
Press the POWER button to start op-
eration.
• The red OPERATION lamp on the unit will
light.
3
Press the TEMPERATURE button to set
the desired temperature.
• The temperature can be set within the range
of 64°F to 86°F.
4
Press the FAN button to set the de-
sired fan speed.
AUTO
QUIET
LOW
HIGH
TO TURN OFF
Press the POWER button again.
• The red OPERATION lamp on the unit will turn
off.
1
4
2
3
"CLOSE" position
1
Remove the exhaust hose (See Page 17)
2
Turn the drainage nozzle to the OPEN position.
3
Pull the stopcock out from the drainage nozzle.
• When the stopcock is removed, a small amount of water
may be discharged from the drainage nozzle.
• Always perform this procedure with the unit turned off.
Drain water will spout out if attempted during operation.
4
I
nsert the hose clamp into a standard commer-
cially-available hose (5/8" inner diameter, 7/8" outer
diameter) and attach the drain grommet to the
hose.
5
Attach the hose to the drainage nozzle, and secure
it with the hose clamp.
• Insert the hose securely into a container with a minimum
capacity of 3 gallons. Be sure to monitor the water level in
the container and empty as necessary. Do not operate in
dehumidify mode for more than 8 hours at a time. Be sure
to empty the water container whenever dehumidify mode is
started. Failure to empty the water container can cause
the container to overflow and cause damage to underlying
materials.
• Set the hose sloping downwards for easier drainage.
Moreover, do not bend the hose at any point, nor allow
the end to be submerged in water.
Dehumidification with no container
2
1
In this mode, the air conditioner dehumidifies the room.
CAUTION
When operating dehumidification with container, the unit generates heat during dehumidifica-
tion mode and the room temperature will rise. Operate dehumidification with no container if
you don't want the room temperature to rise. This will help to slightly drop the room
temperature, but dehumidification performance will become less effective than when operat-
ing dehumidification with container.
1
Press the MODE button to select DEHU-
MIDIFICATION mode.
COOL
DEHUM
FAN
VENT
2
Press the power button to start opera-
tion.
• The red OPERATION lamp on the unit will light.
• The temperature cannot be set.
• The fan speed is preset to AUTO and cannot be
changed.
TO TURN OFF
Press the POWER button again.
• The red OPERATION lamp on the unit will turn off.
Dehumidification with container
Drainage nozzle
Stopcock
Drain grommet
Hose clamp
Hose
I
f draining of the water is not desirable, install the exhaust hose (See Page 16), turn the drainage nozzle to the
CLOSE position, and check that the drainage nozzle is covered with the stopcock. In this operation, the water
tank inside the unit may be full, the unit stops operating and then the TIMER, OPERATION and MEGA COOL
lamps are blinking, depending on room condition. In this case, drain out the water within the unit (See Page 29).
"OPEN" position
Summary of Contents for CV-P09FX
Page 21: ...CVP09FX 4 2 2 PRINTED WIRING BOARD ...
Page 36: ...CVP09FX 6 8 MEMO ...