– 13 –
CD-XP700H
Standard Specification of Stereo System Error Message Display Contents
Error Contents
DISPLAY
Notes
TAPE
Mechanism Error.
'ER-TA**'
00: Tape Mechanism Error.
01: Initial Error.
02:
03:
CD
Pickup Mechanism Error.
'ER-CD**'
01: PU-IN SW Detection NG.
02:
03:
04:
CD Changer Mechanism Error.
'ER-CD**'
10: Changer Error.
(*)
11: Initial Error.
12:
13:
CD DSP Communication Error
'ER-CD**'
31: DSP COMMUNICATION ERROR
Focus Not Match.
'NO DISC'
IL Time Over.
'NOT READ'
TUN
PLL Unlock.
'ER-TU**'
00: TUN Error.
01: PLL Unlock.
02:
03:
(*) CHECKING:
If CD changer mechanism error is detected, 'CHECKING' will be display instead of 'ER-CD**' display 'ER-CD**' will only be display
when CD changer mechanism error had been detected for the 5 th times.
Speaker abnormal detection and +B PROTECTION display
In case speaker abnormal detection or +B PROTECTION had occured, it can be check by pressing 'POWER', 'VIDEO' and 'X-
BASS' key twice. Display will show "S** B**". S is referring to speaker abnormal detection and B is referring to +B PROTECTION.
** is in hex valve.
+B PROTECTION is condition when irregular process occur on power supply line.
All manuals and user guides at all-guides.com